Click on the Modify button to open the Modify time settings window to input the correct local time.
Time server
Setting | Factory Default | Necessity |
IP or Domain address | None | Optional |
(E.g., 192.168.1.1 or time.stdtime.gov.tw |
|
|
or time.nist.gov) |
|
|
The NPort 5410/5430/5430I/5450/5450I uses SNTP
Input the correct “Time Server” IP address or domain address. Once the NPort is configured with the correct Time Server address, the NPort will request time information from the “Time Server” every 10 minutes.
Web/Telnet Console
The “Disable” option for “Web Console” and “Telnet Console” is included for security reasons. In some cases, you may want to disable one or both of these console utilities as an extra precaution to prevent unauthorized users from accessing your NPort 5400. The factory default for both Web console and Telnet console is Enable.
Web console
Setting | Factory Default | Necessity |
Enable or Disable | Enable | Required |
|
|
|
Telnet console |
|
|
Setting | Factory Default | Necessity |
Enable or Disable | Enable | Required |
|
|
|
ATTENTION
If you disable both the “Web console” and “Telnet console,” you can still use NPort Administrator to configure NPort 5400 device servers either locally or remotely over the network. Refer to Chapter 6 for more details.
LCM password protect
Setting | Factory Default | Necessity |
No or Yes | No | Required |
|
|
|
Select Yes to use the web console password to enter the LCM utility. If the console password is blank, the LCM password will also be blank. To enter the password using the LCM buttons, use the scroll buttons to locate a particular character, press SEL, enter the next character in the