Moxa Technologies C168P The followings are pin assignments for various connection options

Page 58
The followings are pin assignments for various connection options:

The followings are pin assignments for various connection options:

Opt8A/S

(DCE, DB25 Female)

2RxD

3TxD

4CTS

5RTS

6DTR

7GND

8DCD

20DSR

Opt8B/C

(DTE, DB25 Male)

2TxD

3RxD

4RTS

5CTS

6DSR

7GND

8DCD

20DTR

Opt8D

(DTE, DB9 Male)

1DCD

2RxD

3TxD

4DTR

5GND

6DSR

7RTS

8CTS

5-2C168P User’s Manual

Image 58
Contents Universal 8 Port Serial Board C168P User’s ManualMay 1999 7th Edition support@moxa.com.twDisclaimer Copyright NoticeTrademarks C168P User’s ManualMOXA Internet Services Chapter 3 Software Installation About This ManualChapter 2 Hardware Installation Chapter 5 Connection Option Opt8x and Cable WiringSerial Programming Tools Hardware InstallationSoftware Installation Table of ContentsTroubleshooting Connection Option Opt8x and Cable WiringTechnical Reference Introduction The Standard Multiport Async SolutionsOverview Hardware Configuration Method SwitchQuick Installation JumperMOXA Serial Comm Tools IntroductionOperating System Support Wide ApplicationsFeatures Check List Opt8A/Opt8B/Opt8SP5 P6 P7 P8 Opt8C/Opt8DP1P2 P3 P4 Opt8F/Opt8ZRS-422 Mode Opt8JRS-422/485 Port Switch of Opt8J Opt8JInstallation Guide RS-485 ModeDefault Settings Hardware InstallationC168P Quick Hardware Installation How to Do Quick Hardware InstallationHardware Installation with IO-IRQ Utility IO-IRQ Utility and Hardware Configuration 2-4 C168P User’s Manual2. Select “Smartio/Industio ISA Family” and press ENTER key Speed 5. Press F10 to save the configuration and exit the utility 2-8 C168P User’s Manual Software Installation Windows NTInstalling Driver 5. Select “MOXA Smartio/Industio Family multiport board” in the “Select OEM Option” dialog box, and then click OK to enter the “Moxa Smartio/Industio Configuration Panel” dialog box to start the installation 3-4 C168P User’s Manual Rx FIFO Trigger Port NumberTx FIFO Size 3-6 C168P User’s Manual Configuring Board and Port In this configuration panel, you may Updating Driver Windows 95/98Removing Driver 1. Run Setup95.exe in the driver diskette Note ! Go directly to the step 7 if you need not change any setting 3-12 C168P User’s Manual If error message like “Smartio C168 Series CAP=0x0180, port 1=COM3 3-14 C168P User’s Manual Updating Driver 3-16 C168P User’s Manual Installing Driver Driver Setup 3-18 C168P User’s ManualSoftware Installation 3-20 C168P User’s Manual You may now enter/modify each port’s configuration. These displayed values are the port initial values as driver is loaded Loading Driver Unloading Driver 3-24 C168P User’s Manual Serial Programming Tools InstallationWindows NT and Windows 95/98 Utilities PComm Programming Library4-2 C168P User’s Manual Diagnostic for MOXA boards only Monitor for MOXA boards under Windows NT Only 4-4 C168P User’s ManualTerminal Emulator Data Scope DOS API-232 Library4-6 C168P User’s Manual There are three major functions in Data Scope utility RS-485 Programming for Opt8J DiagnoseThere are 2 solutions to control RS-485 2-wire transmission Solution4-10 C168P User’s Manual RS-232 Cable Wiring for Opt8A/B/C/D/S Connection Option Opt8x and Cable Wiring2 RxD 3 TxD 4 CTS 5 RTS 6 DTR 7 GND 8 DCD 20 DSR The followings are pin assignments for various connection optionsOpt8A/S DCE, DB25 Female Opt8B/C DTE, DB25 MaleStraight-through Cable Opt8A/S Type 1 To connect C168P to a DTE deviceNull Modem Cable Opt8B/C Type 2 To connect C168P to a DCE device 5-4 C168P User’s ManualConnection Option Opt8x and Cable Wiring Opt8A/S 5-6 C168P User’s ManualDTE Device RS-422 Cable Wiring for Opt8J/F/Z 2 RxD+B 3 TxD+B 14 RxD-A 16 TxD-A 7 GND 4 CTS+B 5 RTS+B RS-422 Pinouts for Opt8J/F/ZOpt8J/F/Z RTS-ARS-422 Device RS-422 Point-to-pointOpt8J/F/Z RS-422 Device NRS-485 Cable Wiring for Opt8J Opt8JRS-422/485 Impedance Matching 5-12 C168P User’s Manual Hardware causes and solutions TroubleshootingGeneral Troubleshooting Hardware Causes and SolutionsSoftware Causes and Solutions Step Step Step Step Step Step A Io-irqStep 8. Power off the PC 3. The COM number of the C168P conflicts with others 4. Windows NT system panic blue screen6-6 C168P User’s Manual Technical Reference SpecificationsAppendix A-2 C168P User’s Manual IO/ Address PC I/O Port Address MapDevice A-4 C168P User’s Manual DB62 Connector PinoutsSignal Pin noCustomer name Company Tel Fax EmailDate Problem Report Form C168P3. Moxa hardware settings 1. Moxa Product C168P Serial Number 2. Moxa Driver VersionReturn Procedure