Moxa Technologies C168P user manual Software Causes and Solutions

Page 70
Software Causes and Solutions:

Software Causes and Solutions:

a.C168P checks the line status (CTS) before it sends data out if the RTS/CTS flow control feature is set to “Enable” in the configuration or application program. Please refer to the “Connection Cable and Cable Wiring” chapter for proper wiring. Check the line status of the suspected port using the diagnostic LED indicators on the mini tester.

b.Perhaps the application controlling the board is not correctly written according to the corresponding API of the operating system. To verify, please run an existing and known good application or the provided utilities by Moxa. For example, under Windows NT and Windows 95/98, Pcomm “Terminal emulator” or “HyperTerminal” utilities are good for testing the COM ports.

3.Why the DOS utility IQ-IRQ can not access C168P to configure? There are several reasons that may lead to this trouble:

a.The user forgets or does not know the Configuration Access Port (CAP) of the board. See next problem 4 for how to solve this problem.

b.The CAP of the board conflicts with other add-on boards’ I/O address. Please change other add-on boards’ I/O address to avoid the conflict.

c.The C168P board is not plugged in a right or good slot. Please plug the board in a good 16-bit ISA slot.

d.The C168P board may malfunction. Please return for repair.

If any existing board has the same I/O address as 0x180, the default CAP address, or the 1st port's I/O address, you must try to avoid the conflict by doing either one the following.

a.Install a jumper (short) at position JP1 on the upper-left corner of the board. This will force the CAP address to 0xA700.

b.Change or disable the existing board's I/O address.

4.What to do if user forgets or does not know the Configuration Access Port (CAP) address of C168P?

The C168P multiport boards are designed without jumper or switch, so the configuration is completed only by DOS utility Io-irq.exe.

6-2C168P User’s Manual

Image 70
Contents Universal 8 Port Serial Board C168P User’s ManualMay 1999 7th Edition support@moxa.com.twDisclaimer Copyright NoticeTrademarks C168P User’s ManualMOXA Internet Services Chapter 3 Software Installation About This ManualChapter 2 Hardware Installation Chapter 5 Connection Option Opt8x and Cable WiringSerial Programming Tools Hardware InstallationSoftware Installation Table of ContentsTroubleshooting Connection Option Opt8x and Cable WiringTechnical Reference Introduction The Standard Multiport Async SolutionsOverview Hardware Configuration Method SwitchQuick Installation JumperMOXA Serial Comm Tools IntroductionOperating System Support Wide ApplicationsFeatures Check List Opt8A/Opt8B/Opt8SP5 P6 P7 P8 Opt8C/Opt8DP1P2 P3 P4 Opt8F/Opt8ZRS-422 Mode Opt8JRS-422/485 Port Switch of Opt8J Opt8JInstallation Guide RS-485 ModeDefault Settings Hardware InstallationC168P Quick Hardware Installation How to Do Quick Hardware InstallationHardware Installation with IO-IRQ Utility IO-IRQ Utility and Hardware Configuration 2-4 C168P User’s Manual2. Select “Smartio/Industio ISA Family” and press ENTER key Speed 5. Press F10 to save the configuration and exit the utility 2-8 C168P User’s Manual Software Installation Windows NTInstalling Driver 5. Select “MOXA Smartio/Industio Family multiport board” in the “Select OEM Option” dialog box, and then click OK to enter the “Moxa Smartio/Industio Configuration Panel” dialog box to start the installation 3-4 C168P User’s Manual Rx FIFO Trigger Port NumberTx FIFO Size 3-6 C168P User’s Manual Configuring Board and Port In this configuration panel, you may Updating Driver Windows 95/98Removing Driver 1. Run Setup95.exe in the driver diskette Note ! Go directly to the step 7 if you need not change any setting 3-12 C168P User’s Manual If error message like “Smartio C168 Series CAP=0x0180, port 1=COM3 3-14 C168P User’s Manual Updating Driver 3-16 C168P User’s Manual Installing Driver Driver Setup 3-18 C168P User’s ManualSoftware Installation 3-20 C168P User’s Manual You may now enter/modify each port’s configuration. These displayed values are the port initial values as driver is loaded Loading Driver Unloading Driver 3-24 C168P User’s Manual Serial Programming Tools InstallationWindows NT and Windows 95/98 Utilities PComm Programming Library4-2 C168P User’s Manual Diagnostic for MOXA boards only Monitor for MOXA boards under Windows NT Only 4-4 C168P User’s ManualTerminal Emulator Data Scope DOS API-232 Library4-6 C168P User’s Manual There are three major functions in Data Scope utility RS-485 Programming for Opt8J DiagnoseThere are 2 solutions to control RS-485 2-wire transmission Solution4-10 C168P User’s Manual RS-232 Cable Wiring for Opt8A/B/C/D/S Connection Option Opt8x and Cable Wiring2 RxD 3 TxD 4 CTS 5 RTS 6 DTR 7 GND 8 DCD 20 DSR The followings are pin assignments for various connection optionsOpt8A/S DCE, DB25 Female Opt8B/C DTE, DB25 MaleStraight-through Cable Opt8A/S Type 1 To connect C168P to a DTE deviceNull Modem Cable Opt8B/C Type 2 To connect C168P to a DCE device 5-4 C168P User’s ManualConnection Option Opt8x and Cable Wiring Opt8A/S 5-6 C168P User’s ManualDTE Device RS-422 Cable Wiring for Opt8J/F/Z 2 RxD+B 3 TxD+B 14 RxD-A 16 TxD-A 7 GND 4 CTS+B 5 RTS+B RS-422 Pinouts for Opt8J/F/ZOpt8J/F/Z RTS-ARS-422 Device RS-422 Point-to-pointOpt8J/F/Z RS-422 Device NRS-485 Cable Wiring for Opt8J Opt8JRS-422/485 Impedance Matching 5-12 C168P User’s Manual Hardware causes and solutions TroubleshootingGeneral Troubleshooting Hardware Causes and SolutionsSoftware Causes and Solutions Step Step Step Step Step Step A Io-irqStep 8. Power off the PC 3. The COM number of the C168P conflicts with others 4. Windows NT system panic blue screen6-6 C168P User’s Manual Technical Reference SpecificationsAppendix A-2 C168P User’s Manual IO/ Address PC I/O Port Address MapDevice A-4 C168P User’s Manual DB62 Connector PinoutsSignal Pin noCustomer name Company Tel Fax EmailDate Problem Report Form C168P3. Moxa hardware settings 1. Moxa Product C168P Serial Number 2. Moxa Driver VersionReturn Procedure