Moxa Technologies user manual DB62 Connector Pinouts, A-4 C168P User’s Manual, Pin no, Signal

Page 78
DB62 Connector Pinouts

DB62 Connector Pinouts

The following lists the pin assignments of the DB62 connector on the bracket.

Pin no.

Signal

Pin no.

Signal

Pin no.

Signal

 

 

 

 

 

 

1

TxD1

22

RxD1

43

CTS1

2

DTR1

23

DSR1

44

RTS1

 

 

24

DCD1

45

GND

3

RxD2

25

TxD2

46

CTS2

4

DSR2

26

DTR2

47

RTS2

5

DCD2

 

 

 

 

6

TxD3

27

RxD3

48

CTS3

7

DTR3

28

DSR3

49

RTS3

 

 

29

DCD3

50

GND

8

RxD4

30

TxD4

51

CTS4

9

DSR4

31

DTR4

52

RTS4

10

DCD4

32

GND

 

 

11

RxD5

33

TxD5

53

CTS5

12

DSR5

34

DTR5

54

RTS5

13

DCD5

 

 

55

GND

14

TxD6

35

RxD6

56

CTS6

15

DTR6

36

DSR6

57

RTS6

 

 

37

DCD6

58

GND

16

RxD7

38

TxD7

59

CTS7

17

DSR7

39

DTR7

60

RTS7

18

DCD7

40

GND

 

 

19

RxD8

41

TxD8

61

CTS8

20

DSR8

42

DTR8

62

RTS8

21

DCD8

 

 

 

 

A-4C168P User’s Manual

Image 78
Contents Universal 8 Port Serial Board C168P User’s ManualMay 1999 7th Edition support@moxa.com.twDisclaimer Copyright NoticeTrademarks C168P User’s ManualMOXA Internet Services Chapter 3 Software Installation About This ManualChapter 2 Hardware Installation Chapter 5 Connection Option Opt8x and Cable WiringSerial Programming Tools Hardware InstallationSoftware Installation Table of ContentsConnection Option Opt8x and Cable Wiring TroubleshootingTechnical Reference The Standard Multiport Async Solutions IntroductionOverview Hardware Configuration Method SwitchQuick Installation JumperMOXA Serial Comm Tools IntroductionOperating System Support Wide ApplicationsFeatures Check List Opt8A/Opt8B/Opt8SP5 P6 P7 P8 Opt8C/Opt8DP1P2 P3 P4 Opt8F/Opt8ZRS-422 Mode Opt8JRS-422/485 Port Switch of Opt8J Opt8JInstallation Guide RS-485 ModeHardware Installation Default SettingsC168P Quick Hardware Installation How to Do Quick Hardware InstallationHardware Installation with IO-IRQ Utility IO-IRQ Utility and Hardware Configuration 2-4 C168P User’s Manual2. Select “Smartio/Industio ISA Family” and press ENTER key Speed 5. Press F10 to save the configuration and exit the utility 2-8 C168P User’s Manual Software Installation Windows NTInstalling Driver 5. Select “MOXA Smartio/Industio Family multiport board” in the “Select OEM Option” dialog box, and then click OK to enter the “Moxa Smartio/Industio Configuration Panel” dialog box to start the installation 3-4 C168P User’s Manual Port Number Rx FIFO TriggerTx FIFO Size 3-6 C168P User’s Manual Configuring Board and Port In this configuration panel, you may Windows 95/98 Updating DriverRemoving Driver 1. Run Setup95.exe in the driver diskette Note ! Go directly to the step 7 if you need not change any setting 3-12 C168P User’s Manual If error message like “Smartio C168 Series CAP=0x0180, port 1=COM3 3-14 C168P User’s Manual Software Installation 3-16 C168P User’s Manual Installing Driver Driver Setup 3-18 C168P User’s ManualSoftware Installation 3-20 C168P User’s Manual You may now enter/modify each port’s configuration. These displayed values are the port initial values as driver is loaded Loading Driver Unloading Driver 3-24 C168P User’s Manual Installation Serial Programming ToolsWindows NT and Windows 95/98 PComm Programming Library Utilities4-2 C168P User’s Manual Diagnostic for MOXA boards only Monitor for MOXA boards under Windows NT Only 4-4 C168P User’s ManualTerminal Emulator DOS API-232 Library Data Scope4-6 C168P User’s Manual There are three major functions in Data Scope utility RS-485 Programming for Opt8J DiagnoseThere are 2 solutions to control RS-485 2-wire transmission Solution4-10 C168P User’s Manual RS-232 Cable Wiring for Opt8A/B/C/D/S Connection Option Opt8x and Cable Wiring2 RxD 3 TxD 4 CTS 5 RTS 6 DTR 7 GND 8 DCD 20 DSR The followings are pin assignments for various connection optionsOpt8A/S DCE, DB25 Female Opt8B/C DTE, DB25 MaleType 1 To connect C168P to a DTE device Straight-through Cable Opt8A/SNull Modem Cable Opt8B/C Type 2 To connect C168P to a DCE device 5-4 C168P User’s ManualConnection Option Opt8x and Cable Wiring 5-6 C168P User’s Manual Opt8A/SDTE Device RS-422 Cable Wiring for Opt8J/F/Z 2 RxD+B 3 TxD+B 14 RxD-A 16 TxD-A 7 GND 4 CTS+B 5 RTS+B RS-422 Pinouts for Opt8J/F/ZOpt8J/F/Z RTS-ARS-422 Device RS-422 Point-to-pointOpt8J/F/Z RS-422 Device NRS-485 Cable Wiring for Opt8J Opt8JRS-422/485 Impedance Matching 5-12 C168P User’s Manual Hardware causes and solutions TroubleshootingGeneral Troubleshooting Hardware Causes and SolutionsSoftware Causes and Solutions Step Step Step Step Step Step A Io-irqStep 8. Power off the PC 3. The COM number of the C168P conflicts with others 4. Windows NT system panic blue screen6-6 C168P User’s Manual Specifications Technical ReferenceAppendix A-2 C168P User’s Manual PC I/O Port Address Map IO/ AddressDevice A-4 C168P User’s Manual DB62 Connector PinoutsSignal Pin noCustomer name Company Tel Fax EmailDate Problem Report Form C168P3. Moxa hardware settings 1. Moxa Product C168P Serial Number 2. Moxa Driver VersionReturn Procedure