Operation

Connect Equipment to the UPS

Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not expect full battery run capability during this initial charge period.

1.Connect equipment to the outlets on the rear panel of the UPS. Do not use extension cords, plug equipment directly into the UPS.

2.Connect the UPS to the building utility power. Connect the UPS to a two-pole,three-wire, grounded receptacle only.

3.Press the ON/OFF button on the front panel of the UPS to apply power to the unit and all connected equipment.

4.To use the UPS as a master on/off switch, turn on all the equipment that is connected to the UPS.

See “Controllable Outlet Groups” on page 7 for information on how to use the Controllable Outlet Groups.

su0439a

Basic Connections

Serial port: Connect to a computer to use power management software.

USB port: Connect to a computer to use power management software.

External Battery Pack connector: Connect external battery packs to provide extended runtime during power outages. The UPS can support up to five external battery packs.

TVSS Ground Screw: The UPS features a Transient Voltage Surge-Suppression (TVSS) screw for connecting the ground lead on surge suppression devices such as a telephone and network line protectors. When connecting a grounding cable, disconnect the UPS from utility power.

Smart-UPS X-Series Operation

3

Image 6 Contents
UPS Overview Smart-UPS Factory Warranty About the UPS SafetyOverview Product OverviewEnvironmental Specifications SpecificationsInstallation Network Management Card External Battery PackOperation Connect Equipment to the UPSBasic Connections Overview Using the display interfaceDisplay Interface Standard MenusAdvanced Menus Start-up Settings ConfigurationUPS Settings General SettingsControllable Outlet Groups Model-specific Controllable Outlet Groups Using the Controllable Outlet Groups and UPS outlets Network Management Card Settings Normally open contacts Emergency Power OffEPO Overview Normally closed contactsDisplay interface indicators flash sequentially TroubleshootingUPS does not provide expected backup time UPS is emitting an audible beeping soundProblem and Possible Cause Replace battery LED is illuminatedDisplay interface has a Site Wiring Fault message Transport the UPS Service and SupportService APC Worldwide Customer SupportSmart-UPS Factory Warranty Limited WarrantyDirectives Type of Equipment Harmonized StandardsApplicable Council Model Numbers990-3458-001 06/2009