Pelco SX8205R manual Installation, Package Contents

Page 10

Installation

PACKAGE CONTENTS

The following items are supplied:

1SX8205R module

1Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output

1Wall clip with two 4-40 x 0.250-inch Phillips pan head screws with lock washers (for attachment of single module to wall)

1SX8205R Unmanaged Ethernet Switch Installation manual (this manual)

SETTING 10BASE-T/100BASE-TX PORT MODES OF OPERATION

NOTE: As a matter of convenience, it is recommended that you verify the modes of operation for each 10BASE-T/100-BASE-TX port and then change the mode settings—if necessary—before mounting the SX8205R module into a rack or onto a wall.

The SX8205R module provides various configuration options that allow you to select the desired modes of operation for each 10BASE-T/100BASE-TX port (ports 1-5). You can select the desired modes of operation by means of a TX Mode switch that is provided on the bottom of the module for each port (refer to Figure 4).

TX MODE SWITCHES - PORTS 1-5

TX Mode

Figure 4. TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-5

10

C2626M (2/07)

Image 10
Contents Ethernet Switch List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionModels Rack mount chassisFront Panel of SX8205R Module Reset Button Restarts the unit Illustrates the front panel of the SX8205R moduleRear Panel Illustrates the rear panel of the SX8205R moduleInstallation Package ContentsTable A. TX Mode Switch Settings Autonegotiation is enabled by defaultFlow control is disabled by default Flow control default settingMounting Mounting the SX8205R Module Into a RackMounting the SX8205R Module Using the Wall Clip Connections 10BASE-T/100BASE-TX connectionsTroubleshooting Amber 10BASE-T link is If 10BASE-T operation is Established Table C. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting 10 for informationDo any of the following as Setting of the remoteNot lit 10BASE-T or 100BASE-TX link Cable Applicable Cannot beIf half-duplex mode is Duplex modeDuplex mode Link Amber Port is set to If 10BASE-T full-duplex100BASE-TX half Green Port is set to If 100BASE-TX full-duplexFlashing green Port is set to Replace cable if it isTable C. Troubleshooting with Rear-Panel Indicators Specifications Link/activity and speed, duplex/collision and speedAppendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001