Pelco SX8205R manual Connections, 10BASE-T/100BASE-TX connections

Page 14

CONNECTIONS

Connections to the SX8205R module are made on the rear panel of the module (refer to Figure 6).

POWER/ALARM CONNECTION

FOR RACK-MOUNTED MODULE

POWER CONNECTION

FOR STAND-ALONE MODULE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

Figure 6. SX8205R Module Connections

As illustrated in Figure 6, SX8205R module connections consist of the following:

Power connection

NOTES:

A 12 VDC or 24 VAC power supply can be used to power the module when used as a stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 0.50 A (minimum output).

In extreme temperature conditions, it is recommended that an industrial-rated outdoor power supply such as the Pelco WCS1-4 power supply be used.

10BASE-T/100BASE-TX connections

NOTES:

Use Cat5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port. Cable length must not exceed 328 feet (100 meters).

The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a straight-through or crossover cable can be used. The ports automatically detect the cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 22 for pinout information.

14

C2626M (2/07)

Image 14
Contents Ethernet Switch List of Tables ContentsList of Illustrations Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionModels Rack mount chassisFront Panel of SX8205R Module Reset Button Restarts the unit Illustrates the front panel of the SX8205R moduleRear Panel Illustrates the rear panel of the SX8205R moduleInstallation Package ContentsTable A. TX Mode Switch Settings Autonegotiation is enabled by defaultFlow control is disabled by default Flow control default settingMounting Mounting the SX8205R Module Into a RackMounting the SX8205R Module Using the Wall Clip Connections 10BASE-T/100BASE-TX connectionsTroubleshooting Amber 10BASE-T link is If 10BASE-T operation is Established Table C. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting 10 for informationDo any of the following as Setting of the remoteNot lit 10BASE-T or 100BASE-TX link Cable Applicable Cannot beIf half-duplex mode is Duplex modeDuplex mode Link Amber Port is set to If 10BASE-T full-duplex100BASE-TX half Green Port is set to If 100BASE-TX full-duplexFlashing green Port is set to Replace cable if it isTable C. Troubleshooting with Rear-Panel Indicators Specifications Link/activity and speed, duplex/collision and speedAppendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001