Schneider Electric 170AMM11030 manual Register for Inputs, Output Operating Range

Page 16

Range

Output Operating Range

 

 

 

 

 

 

 

 

 

 

 

 

Output Voltage

Data is Left Justified

Comment

 

 

 

 

 

 

 

 

Output Range

-10.000 ... +10.000

00382

... 32382

Nominal output voltage

 

 

 

 

 

range

 

 

 

 

 

 

 

Output Over Range

+10.000 ... +10.238

32384 ... 32764

Linear over range

 

 

 

 

 

output voltage

 

 

 

 

 

 

 

 

Output Out of Range

10.238

32766

 

Threshold limited to

 

 

 

(7FFE Hex)

32766 decimal

 

 

 

 

 

 

 

Output Under Range

-10.238 ... -10.000

00002 ... 00382

Linear under voltage

 

 

 

 

 

range

 

 

 

 

 

 

 

 

Output Out of Range

-10.238

00000

 

Threshold limited to

 

 

 

 

 

00000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register for Inputs

Overview

The input register is arranged as follows.

 

 

 

 

 

 

Word

Function

 

 

 

 

 

 

 

1

 

Status word (module status)

 

 

 

 

 

 

 

2

 

State of the 16 discrete inputs

 

 

 

 

 

 

 

3

 

Analog input word channel 1

 

 

 

 

 

 

 

4

 

Analog input word channel 2

 

 

 

 

 

 

 

5 ...

8

Not used

 

 

 

 

 

 

 

 

 

 

 

16

31005009 01 November 2003

Image 16
Contents 170AMM11030 Analog/Digital Momentum I/O Base User Guide VersionSafety Information 170AMM11030 Analog/Digital Momentum I/O Base Front Panel ComponentsOverview Front PanelComponents of the I/O Module LED Illustration The illustration below shows the LEDsFollowing table describes the LEDs DescriptionsSpecifications SpecificationsGeneral Output is protected against short-circuiting and overloadTo ground Number of Channels Output Ranges Type of Signal Fault SensingFault Reporting Operating VoltageInternal Pin Connections Physical DimensionsTerminals on the I/O base and an optional busbar Field Wiring Guidelines Wiring Diagrams Discrete input and output analog input and outputDiscrete I/O DevicesMap Analog I/ORegister for Outputs Word FunctionZero is an illegal value for the parameter field words WordDamage 4x Registers Words 4Register for Inputs RangeOutput Operating Range Input register is arranged as followsDiscrete Input Register Set to an OFF stateBits Description Words 3 Analog Input RegisterWords 5 Words 5 .. are not usedInput Word Analog MapOutput Word Points are field wired to row Discrete I/O Points and IEC Compliant Data MappingInput and Output Ranges Ranges Decimal Values Input Measuring Range ±10Output Measuring Range ±10