Schneider Electric 170AMM11030 manual Safety Information

Page 2

Safety Information

NOTICE

Read these instructions carefully, and look at the equipment to become familiar with

 

the device before trying to install, operate, or maintain it. The following special

 

messages may appear throughout this documentation or on the equipment to warn

 

of potential hazards or to call attention to information that clarifies or simplifies a

 

procedure.

 

The addition of this symbol to a Danger or Warning safety label indicates

 

that an electrical hazard exists, which will result in personal injury if the

 

instructions are not followed.

 

This is the safety alert symbol. It is used to alert you to potential personal

 

injury hazards. Obey all safety messages that follow this symbol to avoid

 

possible injury or death.

 

 

DANGER

 

DANGER indicates an imminently hazardous situation, which, if not avoided,

 

will result in death, serious injury, or equipment damage.

 

 

 

 

 

WARNING

 

WARNING indicates a potentially hazardous situation, which, if not avoided, can

 

result in death, serious injury, or equipment damage.

 

 

 

 

 

CAUTION

 

CAUTION indicates a potentially hazardous situation, which, if not avoided, can

 

result in injury or equipment damage.

PLEASE NOTE

 

 

Electrical equipment should be serviced only by qualified personnel. No responsi-

 

bility is assumed by Schneider Electric for any consequences arising out of the use

 

of this material. This document is not intended as an instruction manual for untrained

 

persons.

 

 

© 2003 Schneider Electric

All Rights Reserved.

 

 

 

2

31005009 00 November 2003

Image 2
Contents 170AMM11030 Analog/Digital Momentum I/O Base User Guide VersionSafety Information Overview 170AMM11030 Analog/Digital Momentum I/O BaseFront Panel Components Front PanelFollowing table describes the LEDs Components of the I/O ModuleLED Illustration The illustration below shows the LEDs DescriptionsGeneral SpecificationsSpecifications Output is protected against short-circuiting and overloadTo ground Number of Channels Output Ranges Fault Reporting Type of SignalFault Sensing Operating VoltageTerminals on the I/O base and an optional busbar Physical DimensionsInternal Pin Connections Field Wiring Guidelines Discrete I/O Wiring DiagramsDiscrete input and output analog input and output DevicesMap Analog I/ORegister for Outputs Word FunctionDamage WordZero is an illegal value for the parameter field words 4x Registers Words 4Output Operating Range Register for InputsRange Input register is arranged as followsBits Description Set to an OFF stateDiscrete Input Register Words 5 Words 3Analog Input Register Words 5 .. are not usedOutput Word Analog MapInput Word Points are field wired to row Discrete I/O Points and IEC Compliant Data MappingInput and Output Ranges Ranges Decimal Values Input Measuring Range ±10Output Measuring Range ±10