Network Technologies CAT5 operation manual Preparation for Installation, Definitions

Page 7

PREPARATION FOR INSTALLATION

Choose a location for the User Station such that cables from the keyboard, mouse, and monitor will reach it.

The CAT5 cables must be run between the locations where the Host Adapter will be connected and User Station is positioned. Be careful to route the cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the signal (i.e. AC motors, welding equipment, etc.) .

NOTE: The installer must ensure that all CAT5 cable between the Host Adapter and User Station, and between each Host Adapter (if more than one) is of the straight-through type and not crossed.

A 120V or 240V electrical supply (depending on the AC adapter being used) must be provided close enough to the position of the User Station to plug the AC adapter into.

All cables should be installed such that they do not cause stress on their connections to the equipment. Extended lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to minimize this.

Properly shut down and disconnect the power from the CPU and devices to be extended. If other equipment is involved whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper disconnection and re-connection procedures before proceeding.

Definitions

Segment

A single or series of CAT5 cable(s) from one user station to one or more Host Adapter(s)

 

that are daisy-chained together. A segment begins with the user station and ends with the

 

last Host Adapter in the daisy chain.

Master ID

A unique number assigned by the administrator to a PRIMUX segment. It is used to identify

 

parts that have been configured by the master authority, particularly Host Adapters that

 

attempt to join the segment.

Master

The ultimate controlling authority in a segment (i.e. the master authority establishes the

Authority

unique I.D. for each Host Adapter). The master authority is part of the User Station.

String

A set of characters, A-Z, 0-9, upper or lower case

Integer

Any whole number (1,2,3…)

Unique ID

Number identifying a Host Adapter to the master authority of a segment.

VGA

Multi-Scan

Monitor

NTI

 

 

 

Favorites

 

 

 

Up

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

PRIMUXTM UZR

Search

CPU

Down

FrontViewofPRIMUX-UZR

CPU1

CPU2

CPU64

PS/2,

PS/2,

PS/2,

USB,

USB,

USB,

ORSUN

ORSUN

ORSUN

Host

Host

Host

Adapter

Adapter

Adapter

CAT5Cable

CAT5Cable

CAT5Cable

 

UPTO1000'

 

SUNKeyboard/Mouse

Figure 1- Typical Application

3

Image 7
Contents Primux Trademark Table of Contents Typical Application Warranty InformationMaterials IntroductionNTI Features and FunctionsDefinitions Preparation for InstallationInstallation of a PS/2 CPU InstallationHost Adapter Installation of a SUN CPU Installation of a USB CPUCPU Installation with PS/2 devices Connecting the CAT5 cable to the Host AdapterUser Station RearViewof PRIMUX-UZRUserStation Installation with USB devicesPower Up for the first time Connecting the CAT5 cable to the User StationRearViewofPRIMUX-UZRUserStation USB HA-USB SUN HA-SUN Daisy-Chained Host AdaptersAdding a Host Adapter to a segment HA-PS2Initial Startup Using the Primux CAT5 KVM SwitchUser Rights vs. Administrator Rights Hot PluggingQuick Connect Change the Default Administrator PasswordAdministrator Login and Password Setup Host AdaptersKeypad Control Standards of OperationSecurity User Login User Access FunctionsAdministrator Login AutologinFunction Enter Administration Mode Administrator only- seeNormal Mode Scan ModeFunction Description Settings MenuHost Adapter Info screen Find Host AdapterFunction Keystroke Value or Action Help Pages OSD Settings MenuFunction Description Keystroke Host Adapters for ScanChange Scan Dwell Time Video Quality AdjustmentAdministration Menu AdministrationHost Adapter List Edit Hosts, Users, and User Station InfoFunction Keystroke Confirmation Parameter Value Required Edit Host AdapterUser List User ListEdit User User InfoFunction Keystroke Parameter Value Add New UserHost Access List Edit User PasswordEdit User Station Change Administrators PasswordSelect Autologon User Use with care, all user configuration Settings will be lostUser Station Info screen Idle TimeoutAlternate OSD screen Alternate OSD KeyFunction Description Keystroke Confirmation Required Update Firmware/Bootloader MenuAcquire/Send DDC Info Configure MAC Host AdaptersSelect Keyboard Language menu Select Keyboard LanguageDistance feet Technical SpecificationsInterconnection Cable Wiring Method Pin Wire Color Pair FunctionNull Modem Cable Pinouts Mating Face 25D Male Connector Female ConnectorCTS RTS DSR DTR DCD Menu QUICK-FIND Keystroke Table Safety and EMC Regulatory StatementsFunction Source Keystroke Sequence Warranty Information