Creating a RAID Set to Incorporate a Preinstalled OS Using the Sun StorageTek Card
The Sun StorageTek card allows you to choose from many RAID configurations. How you configure your system depends on your system requirements and the available hard disk drives in the system. The following example shows how to mirror the preinstalled Windows Server 2003 R2 OS. This is the better option, and all remaining disks (should there be more than 2) are incorporated into a DATA RAID set using the available options as shown in TABLE
You will need the Sun Fire X4150 Server Tools & Drivers CD.
Follow these steps to mirror your configured Windows Server 2003 R2 OS:
1.Select Start and then Sun Link - Online Information.
2.Select Install Supplemental Software.
3.Check Sun StorageTEK Manager.
4.Click Next to install the Sun StorageTEK Manager program.
5.Select Start and then Sun StorageTEK Raid Manager.
6.
7.At the prompt, log in as root, using the OS password that was assigned during installation.
8.Click the SUN STK RAID Controller.
All attached hard disk drives on Enclosure 0 and 1 appear.
9.To mirror the OS,
10.Choose the appropriate RAID option. In this example, select RAID 1 for Mirror.
11.Choose a disk to mirror the OS with, from the physical disk list. Select the hard disk drive that best fits your needs.
12.After you select the hard disk drive, click Next, and then view the configuration summary.
13.Click Apply to start the mirroring process.
You can also click Schedule to perform the mirroring process at a later time.
Chapter 5 Configuring the Preinstalled Windows Server 2003 R2 Operating System 61