Paradyne Hotwiret 7986 Communication Protocol Options, Default Network Destination

Page 12

Table 6. Communication Protocol Options

Node IP Address

Possible Settings: 000.000.000.000 ± 223.255.255.255

Default Setting: 000.000.000.000

Specifies the Node IP address.

￿Node IP Address is only available when the standalone unit is configured as an LTU.

Node Subnet Mask

Possible Settings: 000.000.000.000 ± 255.255.255.255

Default Setting: 000.000.000.000

Specifies the Node Subnet Mask.

￿Node Subnet Mask is only available when the standalone unit is configured as an LTU.

Default Network Destination

Possible Settings: None, COM, DSL

Default Setting: None

Specifies where the default management network is connected. For example, if your default network is connected to the COM port, select COM as the default management network destination.

Communication Port IP Address

Possible Settings: 000.000.000.000 ± 223.255.255.255

Default Setting: 000.000.000.000

Specifies the unit's Communication Port IP Address when the unit is configured as a network communication link.

￿Communication Port IP Address is only used when the Port Use option on the Communication Port Options menu is set to Net Link. If the COM Port IP address is not set (000.000.000.000) the node IP address specified by the Node IP Port will be used.

Communication Port Subnet Mask

Possible Settings: 000.000.000.000 ± 255.255.255.255

Default Setting: 000.000.000.000

Specifies the unit's Communication Port Subnet Mask when the unit is configured as a network communication link.

￿Communication Port Subnet Mask is only used when the Port Use option on the Communication Port Options menu is set to Net Link. If the COM Port IP address is not set (000.000.000.000), the node IP Address will be used.

Communication Port Link Protocol

Possible Settings: PPP, SLIP

Default Setting: PPP

Specifies the unit's Communication Port link layer protocol when the unit is configured as a network communication link.

￿Communication Port Link Protocol is only used when the Port Use option on the Communication Port Options menu is set to Net Link.

12

March 1999

7986-A2-GZ40-00

Image 12
Contents Installation Overview Product Documentation on the World Wide WebConnecting Power to the Unit +24 Vdc Power Supply PinoutsConnecting to the Network Connecting to a DTEConnecting to a System Terminal Network Configuration Entering Identity InformationCO Site Choosing a Configuration Mode Configuring the Unit Using the Configuration MenusIf you select Then Configuration Edit/Display Select To Access To ConfigureNetwork Interface Options 703 Interface Options System Options Communication Port Options 1Communication Port Options 2 Telnet Session Options Node IP Address Possible Settings 000.000.000.000 ± Node Subnet Mask Possible Settings 000.000.000.000 ±Default Network Destination Communication Protocol OptionsCommunity Name Possible Settings Ascii text field, Public Name 1 AccessName 2 Access General Snmp Management OptionsAccess Level Snmp NMS Security OptionsNMS IP Validation Snmp Traps Options Configuring the Unit Using the Internal Switches Handling Precautions for STATIC-SENSITIVE DevicesSwitchpack Locations Switchpack S1 & S2Switchpack S1 Definitions Switch # Allows you to Switchpack S2 Definitions Switch # Allows you to OFF = AutoRate DisabledAll OFF = OFF = Current FirmwareImportant Safety Instructions Warranty, Sales, Service, and Training Information EMI WarningsAsynchronous Terminal Interface Menu Document FeedbackCopyright E 1999 Paradyne Corporation