Paradyne Hotwiret 7986 General Snmp Management Options, Name 1 Access, Name 2 Access

Page 13

Table 7. General SNMP Management Options

SNMP Management

Possible Settings: Enable, Disable

Default Setting: Disable

Enable or disables the SNMP management features.

Community Name 1

Possible Settings: ASCII text field, Public

Default Text: Public

Identifies the name of the community allowed to access the unit's MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.

Name 1 Access

Possible Settings: Read, Read/Write

Default Setting: Read

Determines the access level for Community Name 1.

Community Name 2

Possible Settings: ASCII text field, Public

Default Text: Public

Identifies the name of the second community allowed to access the unit's MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.

Name 2 Access

Possible Settings: Read, Read/Write

Default Setting: Read

Determines the access level for Community Name 2.

7986-A2-GZ40-00

March 1999

13

Image 13
Contents Product Documentation on the World Wide Web Installation Overview+24 Vdc Power Supply Pinouts Connecting Power to the UnitConnecting to a DTE Connecting to the NetworkConnecting to a System Terminal Entering Identity Information Network ConfigurationCO Site Configuring the Unit Using the Configuration Menus Choosing a Configuration ModeIf you select Then Select To Access To Configure Configuration Edit/DisplayNetwork Interface Options 703 Interface Options Communication Port Options 1 System OptionsCommunication Port Options 2 Telnet Session Options Node Subnet Mask Possible Settings 000.000.000.000 ± Node IP Address Possible Settings 000.000.000.000 ±Default Network Destination Communication Protocol OptionsName 1 Access Community Name Possible Settings Ascii text field, PublicName 2 Access General Snmp Management OptionsSnmp NMS Security Options Access LevelNMS IP Validation Snmp Traps Options Handling Precautions for STATIC-SENSITIVE Devices Configuring the Unit Using the Internal SwitchesSwitchpack S1 & S2 Switchpack LocationsSwitchpack S1 Definitions Switch # Allows you to OFF = AutoRate Disabled Switchpack S2 Definitions Switch # Allows you toAll OFF = OFF = Current FirmwareImportant Safety Instructions EMI Warnings Warranty, Sales, Service, and Training InformationDocument Feedback Asynchronous Terminal Interface MenuCopyright E 1999 Paradyne Corporation