Quatech ESC-100 user manual External Connections

Page 26

8 External Connections

RS-232-C devices are classified by their function as either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is defined as the communication source and data communication equipment is defined as the device that provides a communication channel between two DTE-type devices.

Terminal

DTE

Terminal

DTE

RS-232-C

RS-232-C

Modem

DCE

Modem

DCE

Telephone line

Figure 16 --- Use of DTEs and DCEs in a communications link

DTE- and DCE-type devices have complementary pinouts to allow terminals and modems to be connected directly using a one-to-one cable as shown in Figure 17. In many applications, DCEs are unnecessary, and in these cases a cable called a "null modem cable" or "modem eliminator cable" is used to directly connect two DTE-type devices. A typical null modem cable is also shown in Figure 17.

(3)

RxD

TxD

(3)

(3)

RxD

RxD

(3)

(2)

TxD

RxD

(2)

(2)

TxD

TxD

(2)

(4)

RTS

CTS

(4)

(4)

RTS

RTS

(4)

(5)

CTS

RTS

(5)

(5)

CTS

CTS

(5)

(20)

DTR

DSR

(20)

(20)

DTR

DTR (20)

(6)

DSR

DTR

(6)

(6)

DSR

DSR

(6)

(8)

DCD

DCD

(8)

(8)

DCD

DCD

(8)

(22)

RI

RI

(22)

(22)

RI

RI

(22)

(7)

GND

GND

(7)

(7)

GND

GND (7)

 

Typical DTE-to-DCE cable

 

Typical DTE-to-DTE null modem cable

Figure 17 --- Cabling requirements for RS-232-C devices

(cables using 25-pin connectors shown)

Quatech ESC-100 User's Manual

26

Image 26
Contents ESC-100 Warranty Information Page Declaration of Conformity Enhanced Serial Adapter Identification Address Map and Special RegistersBase Address and Interrupt Level IRQ Viewing Resources with Device ManagerConnector Type General InformationFeatures IND Option --- Surge Suppression UpgradeEnable Scratchpad Register SPAD, J4 Hardware ConfigurationFactory Default Configuration Force High-Speed Uart Clock X2, X4, or X8, J1-J3 Clock multiplier jumper optionsHardware Installation Jumper/connector locationsPort Address Range Enabling the Special Registers Interrupt Status RegisterOptions Register Bit Name DescriptionClock Rate Multiplier RR1 RR0Windows Configuration Windows MillenniumWindows Windows Windows Windows NT Viewing Resources with Device Manager Page DOS and Other Operating Systems DOS and other operating systemsQTPCI.EXE Basic Mode display QTPCI.EXE Expert Mode display OS/2 External Connections ESC-100D Channel Output Configuration ESC-100D Connector PinoutsESC-100D Output Connectors CTS DSR ESC-100M only PCI Resource Map INTA#10Specifications Maximum Load pF Data Rate 10% 15% 20% 25% Kbaud Trans Time Troubleshooting Computer will not boot upESC-100D/M Revision March