Quatech ESC-100 user manual Troubleshooting, Computer will not boot up

Page 34

11 Troubleshooting

Listed here are some common problems and frequent causes of those problems. If the information here does not provide a solution, contact Quatech technical support.

Any unauthorized repairs or modifications will void the ESC-100's warranty.

Computer will not boot up.

1.Is the ESC-100 properly inserted? Remove the card and try again. Perhaps try a different expansion slot.

2.Ensure that an ISA-bus card is not using the same IRQ that the PCI BIOS tries to assign to the ESC-100. Most computers have BIOS setup options to reserve IRQs for either ISA or PCI use. Try reserving the IRQ for the ISA card. The BIOS will automatically choose a different IRQ for the ESC-100. An address conflict is unlikely because most PCI-based computers will assign I/O addresses in such a way that they cannot conflict with ISA-bus devices.

3.The ESC-100 may be defective. Contact technical support for instructions.

Cannot communicate with other equipment.

1.Are the cable connections correct? Are the cables securely attached?

2.Is the software configured with the correct base address and IRQ information for the ESC-100? (This is mainly a DOS issue.)

3.Is the device driver installed?

4.If you are trying to communicate with another DTE, a null-modem cable will be required.

5.If possible, use a loopback connector to test the port. This connector needs to connect the following sets of signals on a D-25 connector:

TxD and RxD (pins 2 and 3)

RTS and CTS (pins 4 and 5)

DCD, DTR, DSR, and RI (pins 8, 20, 6 and 22)

Quatech ESC-100 User's Manual

34

Image 34
Contents ESC-100 Warranty Information Page Declaration of Conformity Enhanced Serial Adapter Identification Address Map and Special RegistersBase Address and Interrupt Level IRQ Viewing Resources with Device ManagerConnector Type General InformationFeatures IND Option --- Surge Suppression UpgradeFactory Default Configuration Hardware ConfigurationEnable Scratchpad Register SPAD, J4 Force High-Speed Uart Clock X2, X4, or X8, J1-J3 Clock multiplier jumper optionsHardware Installation Jumper/connector locationsPort Address Range Enabling the Special Registers Interrupt Status RegisterOptions Register Bit Name DescriptionClock Rate Multiplier RR1 RR0Windows Configuration Windows MillenniumWindows Windows Windows Windows NT Viewing Resources with Device Manager Page DOS and Other Operating Systems DOS and other operating systemsQTPCI.EXE Basic Mode display QTPCI.EXE Expert Mode display OS/2 External Connections ESC-100D Channel Output Configuration ESC-100D Connector PinoutsESC-100D Output Connectors CTS DSR ESC-100M only PCI Resource Map INTA#10Specifications Maximum Load pF Data Rate 10% 15% 20% 25% Kbaud Trans Time Troubleshooting Computer will not boot upESC-100D/M Revision March