Patton electronic 1092ARC 3 V.52 BER Test Pattern Generator, Patton Model # Description

Page 18

1.Activate RDL. This may be done in three ways:

-Move the front panel toggle switch to the Left to “Remote”.

-Raise the RDL signal on the interface (see Appendix C).

-Set Remote Loopback from the VT100 screen.

Note: Remote Loopback cannot be activated until approximately 45 seconds after the two modems have linked to each other.

2.Perform a V.52 BER test as described in Section 5.2.3. If the BER test equipment indicates a fault, and the Local Line Loopback test was successful for both Model 1092ARCs, you may have a problem with the twisted pair line between the modems. You should then check the twisted pair line for proper connections and continuity.

5.2.3V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests* (or with Local Line Loopback tests), follow these instructions:

1.Locate the “511/511E” toggle switch on the front panel of the 1092ARC and move it to the left. This activates the V.52 BER test mode and transmits a “511” test pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink sporadically.

2.If the above test indicates no errors are present, move the

V.52 toggle switch to the right, activating the “511/E” test with errors present. If the test is working properly, the local modem's red “ER” LED will blink approximately once per second. A successful “511/E” test will confirm that the link is in place, and that the Model 1092ARC’s built-in “511” generator and detector are working properly.

APPENDIX A

PATTON ELECTRONICS MODEL 1095RC

FACTORY REPLACEMENT PARTS

AND ACCESSORIES

Patton Model #

Description

1001RPEM-RAC

120/240V Rear Power Entry Module

1001RPSM-RUI

120/240V Front Power Supply Module

1001RPEM-RDC

DC Rear Power Entry Module

1001RPSM-R48A

48V Front Power Supply Module

1001R14P

Rack 14 Slot 2U Chassis Only

1001R14P/R48V

Rack 14 Slot 2U w/Dual Universal

 

Input 48VDC Power Supplies

1001R14P/RUIA

Rack 14 Slot 2U w/Dual Universal

 

Input 90-260VAC Power Supplies

 

European Power Cord

1001R14P/RUIC

Rack 14 Slot 2U w/Dual Universal

 

Input 90-260VAC Power Supplies

 

Austrialia Power Cord

1001R14P/RUID

Rack 14 Slot 2U w/Dual Universal

 

Input 90-260VAC Power Supplies

 

UK Power Cord

1001R14P/RUIG

Rack 14 Slot 2U w/Dual Universal

 

Input 90-260VAC Power Supplies

 

India Power Cord

1001R14P/RUIK

Rack 14 Slot 2U w/Dual Universal

 

Input 90-260VAC Power Supplies

 

US Power Cord

1001RCM12545

DB-25/RJ-45 Rear Card

1001RCM125TB

DB-25/TB Rear Card

1001RCM13445

M/34/RJ-45 Rear Card

1001RCM134TB

M/34/TB Rear Card

1001RCM11545

DB-15/RJ-45 Rear Card

1001RCM115TB

DB-15/TB Rear Card

1001MC

Management Card

IM2RC/F

64K/G703 Rear Card

IM2RC/B

RS-530 Interface Rear Card

IM2RC/D

X.21 Interface Rear Card

1180RC DB

V.35 Daughter Board

0516FPB1

Single Width Blank Front Panel

0516FPB4

4-Wide Blank Front Panel

0516RPB1

Single Width Blank Rear Panel

0516RPB4

4-Wide Blank Rear Panel

056S1

Set of 16 #4 pan head screws/washers

10-25M/35M-1

Cable, 6 ft, DB-25 male to M/34 male

1010-10

Terminal Block, 2 Position, Male

07M1092ARC

User Manual

33

34

Image 18
Contents User Manual Radio and TV Interference Table of ContentsWarranty Information CE NoticeEmail support@patton.com, or Service iNFORMATIONFeatures General InformationConfigure the Hardware Switches 1092A Snmp Management SolutionsConfiguration HTTP/HTML ManagementReversible Interface Driver Board Configuration Switch Set S1Switches S1-1 and S1-2 Data Rate S1 Summary TableSwitches S1-6 and S1-7 Transmit Clock Source Switch S1-3 Data Set Ready During Local Line Loopback TestSwitches S1-4 Management Setting Switch S1-8 Response to Remote Loop RequestConfigure the Software Switches S5 Summary TableMain Menu Option 2 Display Hardware Configuration Configure the Local 1092ARCMain Menu Option 1 Display Active Configuration Main Menu Option 3 Display Software ConfigurationDTE Rate Main Menu Option 4 Setup Software ConfigurationClock Mode Data FormatResponse to Remote Digital Loop Wire/4-Wire SelectionDSR During Local Line Loop DTE Controlled Local Line LoopOFF Strap Function Position 1&2 Position 2&3 Configure the Rear Interface CardInterface Card Strap Summary Table #1 DTE Shield DB-25 Pin 1 & Frgnd JB3Interface Card Strap Summary Table #2 Model 1001RCM13445 Rear Card Strap SettingsModel 1001RCM11545 Rear Card Strap Settings DTE Shield DB-15 Pin 1 & Frgnd JB3Model 1001R14 Rack Chassis InstallationRack Power Supply For more information Connect to a DTE Device Install the Model 1092ARC Series Into the Chassis Wire the Model 1092ARC Series Connect to a DCE DeviceTD & RD Signal PIN#LED Status Indicators CTSTest Modes Local Line Loopback LLBRemote Digital Loopback RDL 3 V.52 BER Test Pattern Generator Patton Model # DescriptionAppendix B Model 1092ARC Terminal Interface PIN Assignment 34F Connector-DCE InterfaceDB-25F Connector-DCE RS-232 Interface Patton Model 1092ARC Terminal Interface PIN AssignmentRJ45 Connector RJ-45 Connector on 1000CC CardEIA Pin Number Signal