Patton electronic 2160 Series, 07M2160-GS manual Pvid

Page 78

Model 2160 Series Getting Started Guide

 

 

 

5 • Console and Telnet configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

-----------------------------------------------------------------------------

 

 

 

 

 

Command: setup vlan link_mode <1~6> <AccessTrunk>

 

 

 

 

 

 

 

Message: Please input the following information.

 

 

 

 

 

 

 

Port index <1~6>: 1

 

 

 

 

 

 

 

 

 

 

 

Port link type (TAB Select) <Access>:

 

 

 

 

 

 

 

-----------------------------------------------------------------------------

 

 

 

 

Table 22 shows the options available within the 802.1Q Tag VLAN command menu:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access

 

 

The port can receive or send untagged packets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk

 

 

The port can receive or send tagged packets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 22. 802.1Q VLAN Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

2

3

4

5

 

6

 

 

No.

 

VID

 

LAN1

 

LAN2

LAN3

LAN4

Line

Sniffing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVID

 

 

 

 

 

 

 

 

 

 

 

 

Link Type

 

Access

Access

Access

Access

Access

Access

 

 

 

 

 

 

 

Trunk

 

Trunk

Trunk

Trunk

Trunk

Trunk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port-Based VLAN. With port-based VLAN, the port is assigned to a specific VLAN independent of the user or system attached to the port. This means all users attached to the port should be members in the same VLAN. The network administrator typically performs the VLAN assignment. The port configuration is static and cannot be automatically changed to another VLAN without manual reconfiguration.

You can set up Port-Based VLAN using the method for 802.11Q. However, VID , PVID or link type do not matter for Port-Based VLAN. Use the list command to check the status of the VLAN.

-----------------------------------------------------------------------------

Virtual

LAN Parameter

 

 

VLAN Mode

 

 

 

: Port-Based VLAN

Virtual

LAN Table

 

 

 

No LAN1 LAN2 LAN3 LAN4

Line Sniffing

--

----

----

----

----

---- --------

1

1

1

1

1

1

1

2

-

-

-

-

-

-

3

-

-

-

-

-

-

4

-

-

-

-

-

-

5

-

-

-

-

-

-

6

-

-

-

-

-

-

7

-

-

-

-

-

-

8

-

-

-

-

-

-

-----------------------------------------------------------------------------

Setup Command Menu

78

Image 78
Contents CopperLink Model 2160 Series Mailsupport@patton.com Summary Table of Contents Table of Contents Web configuration Console and Telnet configuration Contacting Patton for assistance Port pin-outs List of Figures Model 2160 Series Getting Started Guide List of Tables About this guide AudienceStructure Precautions Impaired functioningSafety when working with electricity Tected by a circuit breakerModel 2160 first Preventing Electrostatic Discharge Damage General observationsTypographical conventions used in this document General conventionsChapter contents General informationModel 2160 overview ModelWAN 1-4 Link Model 2160 front panelLED descriptions LAN 1-4100MModel 2160 rear panel Port descriptionsReset button Ground terminalApplications overview Introduction Typical applicationDistance charts Distance Chart 2160 Series Standard SettingDistance Chart 2160 Series High Speed Setting Hardware installation Planning the installation Network diagram AC Power MainsIP related information Location and mounting requirements Installing the ModelConnecting cables Unpacking the ModelGrounding the Model 2160 and connecting power Grounding studConsole configuration requirements Configuring the ModelWeb configuration requirements Telnet configuration requirementsWeb configuration Web configuration Setting Up the WMI TCP/IP setupSystem Login Operation mode and Mgmt port Basic Configuration OptionsSubnet Mask Host Name Soho Dhcp serverLAN IP Address Subnet Mask Gateway DNS Server 1 DNS Server 2 Review and save basic setup changes Review and save basic setup changesAdvanced Configuration Options Line TypeAnnex Type SNR Margin Tcpam TypeMain Rate Line ProbeVlan VID 802.1Q Tag-Based Vlan 1Q Tag-Based Vlan802.1Q Vlan Web configuration Port-Based Vlan Port-Based VlanPort-Based QinQ Tpid Tag Protocol Identifier Enter 33024 for IEEE802.1QQuality of Service QoS Port Based Priority QoS Port Based PriorityVlan Tag Priority QoS Vlan Tag PriorityDefault Service by WRR IP Dscp PriorityClass Delay NormalStays the same link layer and routing protocol keep alive Throughput Normal High ReliabilityQoS IP Dscp Priority Rate Control Rate ControlStatus Options Line StatusMgmt Status Administration Options Security AdministrationLAN Status User Profiles Remote Management HostsSnmp Administration Snmp AdministrationCommunity Pool Snmp community pool configurationUtility Options Trap Host PoolSystem Information Configuration Tool Configuration ToolUpgrade LogoutRestart RestartConsole and Telnet configuration Dhcp Server Dhcp Fixed Host DNS Proxy Host NameConsole and Telnet configuration Ctrl + C Quit configuring the item Ctrl +Q Access help Log in using TelnetInterface commands Log in to the console interfaceWindow structure Product name Line BridgeMain Menu Tree Menu tree for authorized usersMenu tree for unauthorized users Main screen for authorized usersEnable Command Menu Setup Command Menu LineLink Wire modelMode Maximum Main RateClear IP Address Subnet MaskVlan Mode Disable 802.1Q Tag Vlan Port-Based VlanSetup Command Menu Pvid QoS Mode QoSQueue Weight QoS Mode Weight ValueQueue Schedule Port-Based Priority QoS Vlan Tag Priority QoSIP Dscp Priority QoS Vlan Tag Index 0 1 2 3 4 5 6 Queue IndexPort ListRate Port LineMgmt Dhcp Server Dhcp Fixed HostFactory Default DNS ProxyHost Name Status Command Menu Interface StatusInterface System Show Command MenuWrite Command ConfigReboot Command Ping CommandAdministration Command Menu User ProfileModify/Add User Security Telnet TCP PortLegal IP Address Pool Snmp CommunityReadWrite Trap hostReadOnly DeniedSupervisor Password and ID Supervisor PasswordSupervisor ID Backup system configuration Utility Command MenuUpgrade main software Restore system configurationExit Command Contacting Patton for assistance Warranty coverage Contact informationReturn for credit policy Out-of-warranty serviceReturns for credit RMA numbersAppendix a Compliance information CE Declaration of Conformity ComplianceRadio and TV interference FCC Part Authorized European RepresentativeAppendix B Specifications Management Connector Line ConnectorEthernet Connector Line ModulationDimensions Front Panel IndicatorsPower Supply WeightAppendix C Port pin-outs Console port EIA-561 RJ-45 8-pin portEthernet Line CopperLink

2160 Series, 07M2160-GS specifications

The Patton Electronic 07M2160-GS is a kind of versatile and innovative device that falls within the 2160 Series of products. This series is renowned for its robust architecture, delivering reliable performance across various telecommunications applications. The 07M2160-GS is specifically designed to provide high-quality services for businesses that require efficient data communication solutions.

One of the main features of the 07M2160-GS is its impressive ability to support multiple communication protocols, allowing seamless integration into existing network infrastructures. This versatility makes it suitable for a wide array of applications, ranging from legacy systems to modern VoIP communications. The device is equipped with advanced bridging and routing capabilities, ensuring that network traffic is efficiently managed and directed.

The 07M2160-GS also embraces a set of cutting-edge technologies that enhance its performance. It typically incorporates features such as Quality of Service (QoS) management. This technology is crucial in prioritizing essential data packets to ensure that voice and video communications are prioritized over less critical data, thus improving the overall user experience. Additionally, the device supports robust error correction algorithms, further enhancing the reliability of data transmissions.

Another characteristic that stands out in the 2160 Series is the ease of installation and configuration. The 07M2160-GS often comes with a user-friendly interface, allowing system administrators to set up and manage the device without extensive training. This ease of use is complemented by comprehensive support resources provided by Patton Electronics, ensuring that customers can troubleshoot and optimize their devices effectively.

Furthermore, the 07M2160-GS is designed with scalability in mind, making it an ideal choice for growing businesses. The modular architecture allows for easy upgrades and expansions, ensuring that organizations can adapt their communications infrastructure as their needs evolve.

In summary, the Patton Electronic 07M2160-GS offers an exemplary combination of advanced features, cutting-edge technologies, and user-friendly characteristics. This device is well-suited to meet the demands of modern telecommunications, ensuring that businesses can maintain reliable communication channels as they grow and adapt to an ever-changing digital landscape.