Patton electronic 2960, 2996 user manual Saving your configuration

Page 45

Model 2960/2996 RAS User Manual

3 • Configuring the RAS for operation

 

 

For T1 lines with ESF/B8ZS this should be set to linkYellowFormatDL(2).

7.Click on Submit Query.

Channel assignment

This section describes configuring the RAS so it will know which channels are active. Do the following:

1.Select T1/E1 Link on the Configuration Menu. The T1/E1 Link Activity window appears (see figure 28 on page 39).

2.Click on Channel Assignment. The WAN Circuit Channel Assignment window appears (see figure 33 on page 43).

3.Click on the Dialin button under the Set all channels to: section. Channels 25 through 30 are ignored for T1/PRI lines.

4.Click on Submit Query.

Saving your configuration

The basic configuration for the RAS is now finished. Do the following to save your configuration settings:

1.Select Home on the Configuration Menu. The Home window appears (see figure 18 on page 31).

2.Click on the Record Current Configuration button (see figure 20 on page 33).

Note Failing to click on the Record Current Configuration button before you power down or reset the RAS will cause your changes to be lost.

3.The Import/Export function enables you to make a backup (or export) copy of your access server’s config- uration parameters. By exporting the configurations, the saved files can quickly be loaded (or imported) into a replacement access server—greatly speeding up the installation process should an access server need replacing.

Note All actions for Import/Export require superuser access privileges.

Saving your configuration

45

Image 45
Contents Remote Access Server RAS Mailsupport@patton.com Contents Operation and shutdown Contacting Patton for assistance Radio and TV Interference Industry Canada NoticeFCC Information CE Notice FCC Part 68 Compliance StatementStructure AudiencePrecautions Typographical conventions used in this documentGeneral conventions Mouse conventions Introduction Chapter contentsModel 2960/2996 RAS Ultra Red version shown Model 2960/2996 Remote Access Server overviewWAN Hardware overviewPower system SignalingTemperature ModemsPhysical dimensions Management servicesSecurity Model 2960/2996 front panel LEDs LED displayApprovals Software overview Software overviewHardware installation RAS chassis installation IntroductionUnpacking the Model 2960/2996 RAS Cable installation Installing the power cablesAttaching the cable retainer clip Grounding the Model 2960/2996 Power cable retainer clipModel 2960/2996 network and configuration ports Connecting the Ethernet portsConnecting to the T1/E1/PRI WAN ports Connecting the EIA-561 RS-232 configuration portT1/E1/PRI RJ-48C pinout diagram Completing the hardware installationConfiguring the RAS for operation Preparing the RAS for configuration Configuration prerequisitesConfigure the COM port settings as shown in figure COM properties Login window Opening the RAS Web Administration Pages Configuring the RAS with a Web browserHome page window panes Home page overviewImmediate Actions buttons No Validation Configuring simple authenticationStatic User Authentication Configuration windowDial-in main window Configuring dial-in user informationModify Dial-In window, Login section Modify Dial-In window, Domain Name Server section Configuring the default gatewayT1/E1 Link Activity window Configuring line settings and signaling for E1Pinout for loopback to test WAN port Configuring the line settingsSetting the line signaling for an E1/R2 line Setting the line signaling for an E1/PRI Isdn lineMFR Version 2 Modify window Channel assignment Configuring line settings and signaling for T1Setting the line signaling for a robbed-bit T1 line Setting the line signaling for an ISDN/PRI lineSaving your configuration Import/Export main window Completing the installation Configuring the RAS for operation Operation and shutdown De-activating the RAS Activating the RASTroubleshooting and maintenance Symptoms Power Fault analysisEthernet Maintenance Periodic maintenanceExporting the current RAS configuration CalibrationMaintenance Removing the defective RAS Installing the replacement RAS Verifying the hardware installationImporting a saved configuration Configure the COM port settings as shown in figure Press Return to display the login window see figure Actions Completing the installation Contacting Patton for assistance Out-of-warranty service Warranty coverageContact information Returns for creditReturn for credit policy RMA numbersShipping instructions

2960, 2996 specifications

The Patton Electronics 2996 and 2960 series encapsulates a line of robust communication devices designed for versatile applications in data transmission and connectivity. These models cater to various industries, providing reliable performance, ease of use, and advanced features.

The Patton 2996 is known for its adeptness at functioning as a high-speed T1/E1 access device, making it ideal for businesses seeking efficient integration into existing networks. With a dual-channel design, the 2996 can support multiple voice and data streams simultaneously, facilitating seamless communication. Enhanced with built-in diagnostics and a user-friendly web interface, network administrators can easily monitor performance and configuration settings.

On the other hand, the Patton 2960 series includes HD voice gateway features, allowing users to connect legacy telephone systems with VoIP networks. This series stands out with its ability to support a myriad of protocols, such as SIP and H.323, ensuring compatibility with various telecommunication standards. By bridging traditional telephony with modern IP networks, the 2960 fosters an adaptable and scalable communication environment for businesses of all sizes.

Both models are equipped with comprehensive security features, including robust encryption protocols, ensuring that data remains protected during transmission. Additionally, they support Quality of Service (QoS) parameters to prioritize voice traffic, minimizing latency and enhancing the clarity of calls.

The hardware design of the Patton 2996 and 2960 series emphasizes reliability and durability. With solid construction, these devices are engineered to withstand challenging conditions, making them suitable for deployment in diverse environments. The easy installation process, coupled with wide-ranging support for various interfaces, ensures they can integrate smoothly with existing infrastructure.

In summary, the Patton Electronics 2996 and 2960 series represent high-quality communication solutions that blend advanced technology with practical features. Their capabilities to support both legacy and modern systems make them invaluable assets for any organization looking to enhance its communication effectiveness and efficiency. Whether it's for data transmission or voice gateway functionality, these models deliver reliable performance and a range of features tailored to meet the demands of today’s ever-evolving connectivity landscape.