The RTM IP card on the rear of the RMX 2000 provides connectivity to all the MCU modules. Use the following procedure to replace the RTM IP card:

1Ensure that the power switch on the RMX 2000 is turned OFF (O).

2Unscrew the captive screws on the rear panel of the RMX 2000 that secure the RTM IP card.

3Use the metal ejector levers to pull the RTM IP card out of its slot in the backplane.

4Carefully slide the RTM IP card out through the rear panel.

5On the card to be installed, move the ejector levers to their fully open position.

6Slide in the replacement RTM IP card.

7Push the RTM IP card firmly into the backplane, making sure it is properly seated in its slots.

8Ensure that the metal ejector levers are fully retracted into their housings.

9Tighten the captive screws on the rear panel of the RMX 2000 that secure the RTM IP card.

10Turn ON the RMX 2000.

For more information on the Card Configuration Modes after reset, see "MPM/

MPM+ and MPMx Media Cards” on page 1-16.

1-39

Image 45
Contents Polycom RMX 2000 Hardware Guide USA United States Federal Communication Commission FCC Regulatory NoticesChinese Communication Certificate Singapore Certificate Table of Contents MCU Installing the Replacement MPM/MPM+/MPMx CardHardware Description Main FeaturesRMX 2000 Specifications Conferencing Capacities RMX 2000 System CapacitiesSystem Functions MPM Mode MPM+ Mode MPMx Mode MPM+ Resource CapacitiesVSW 2Mb 160 VSW 4Mb VSW 6Mb Safety Requirements Rack Mount Safety PrecautionsSite Requirements Installation Precautions RMX 2000 Front Panel RMX 2000 ComponentsCntl CPU Component DescriptionComponent Description RTM IP RMX 2000 Rear PanelManagement Network on page G-1 Following items appear on the RMX 2000 rear panelLAN port RTM IsdnCables Connected to the RTM IP & Isdn Cards All external connectors are located on the rear panelMPM/MPM+ and MPMx Media Cards Resource Type Maximum Possible Resources Per CardMPMx Card Resources Bandwidth Type MPM+ Resource Capacities per Card Type AssemblyHD720p HD1080p @30fps @60fps MPM+ Up toMPMx, MPM+ and MPM Modes MPMx Resource Capacities per Card AssemblyAudio algorithm is not supported with MPMx Resource Type MPMx S MPMx DAll MPM MPMx OnlyMPM+ MPMx Only Both MPM cards are enabled An RMX has two MPM cards installedInserted MPMx card is enabled Remove one MPM card Insert one MPMx cardAn RMX has one MPMx card installed Remaining MPM card is disabledMPMx card is enabled Inserted MPM card is disabledRMX 2000 Front Panel LEDs RMX 2000 LEDsFollowing items appear on the RMX 2000 front panel ComponentCard Insertion Initiated If during Card removal Initiated The cardCntl Unit RMX 2000 Rear Panel LEDs Following LEDs appear on the RTM IP cardLED Color Description Name ShMG LEDs Function Name Following LEDs appear on the RTM IsdnRMX 2000 General Information dialog box opens RMX Chassis TypesComponent Replacement Types of Ejector Levers on RMX Components Fully Open The card is released from the MCU housingReplacing the Cntl Module Hardware Description Replacing the Power Supply Module Replacing the Fan Drawer Removing the MPM/MPM+/MPMx Card from the MCU Replacing a Faulty MPM/MPM+/MPMx CardInstalling the Replacement MPM/MPM+/MPMx Card Installing a New MPM/MPM+/MPMx Card in a Powered On RMXReplacing a RTM Isdn Card PRI Cables Replacing the RTM IP Card