- –VP 1608 Overview

5

#

Feature

Function

1

IR Receiver

The LED is illuminated when receiving signals from the Kramer Infra-red remote control transmitter

2

POWER Switch

Illuminated switch supplying power to the unit

3

OUTPUT SELECTOR

Select the output to which the input is switched (from 1 to 8)

 

Buttons

 

4

INPUT SELECTOR Buttons

Select the input to switch to the output (from 1 to 16)

 

 

Use the INPUT SELECTOR buttons to store/recall the input/output configurations (refer to Section 7.4)

5

ALL Button

Pressing ALL followed by an INPUT button, connects that input to all outputs

 

 

For example, press ALL and then INPUT button # 2 to connect input # 2 to all the outputs

6

OFF Button

Pressing OFF after pressing an OUTPUT button disconnects that output from the inputs. To disconnect

 

 

all the outputs, press the ALL button and then the OFF button

7

TAKE Button

Pressing TAKE toggles the mode between the CONFIRM mode and the AT ONCE mode (user

 

 

confirmation per action is unnecessary)

8

VIDEO Button

When pressed actions relate to video

9

AUDIO Button

When pressed actions relate to audio

10

AFV Button

When pressed audio channels follow the video channels. The button is illuminated when the AFV mode

 

 

is selected

11

STO Button

Pressing STO (STORE) followed by an input button stores the current setup

12

RCL Button

Pressing the RCL (RECALL) button and the corresponding input button recalls a setup

 

 

After pressing the button, the stored status flashes. Pressing a different input button lets you view (only

 

 

view, nothing is implemented at this stage) another setup. After making your choice, pressing the RCL

 

 

button again implements the new status

13

LOCK Button

Pressing the LOCK button for more than 2 seconds, engages/disengages the front panel switches

14

INPUT STATUS 7-segment

Displays the selected input switched to the output (marked above each input)

 

Display

Also displays the number included in the product name and the firmware version number, as Section 7.8

 

 

describes

Image 9
Contents VP-1608 Page Contents Figures Introduction Achieving the Best Performance Getting StartedDefining the VP-1608 16x8 RGBHV/Balanced Audio Matrix OverviewVP 1608 Overview Feature Function Overview Flash Program Switch Installing in a Rack Connecting a Single VP-1608 Connecting the VP-1608 Connecting a PC or Controller to the RS-485 Port Connecting to the VP-1608 via RS-232Setting the Machine # DIP-Switches Setting the Delay DIP-Switches Connecting via a PC or Serial Controller Connecting Multiple VP-1608 UnitsControl Configuration via RS-232 and RS-485 Connecting via an RS-485 ControllerVP-1608 Connecting Multiple VP-1608 Units Operating Your VP-1608 16x8 RGBHV/Balanced Audio Matrix Using the Audio-Follow-Video or Breakaway OptionTo set the breakaway option Switching OUT-IN CombinationsToggling between the AT Once and Confirm Modes Confirming SettingsTo store the current status in memory, do the following Storing/Recalling Input/Output ConfigurationsTo delete an input/output configuration, do the following To recall an input/output configuration, do the followingResetting the VP-1608 16x8 RGBHV/Balanced Audio Matrix Adjusting the Audio Gain ControlLocking and Unlocking the Front Panel To lock the VP-1608Resetting to the Current Status Displaying Unit CharacteristicsConnecting the PC to the RS-232 Port Flash Memory UpgradeDownloading from the Internet To download the up-to-date file from the InternetUpgrading the Firmware To upgrade the firmware, follow these stepsAT89C51RD2 Click OK and select Load Hex from the File menu RS-232 Window If an error message Not Finished shows, click Run again Inputs Technical SpecificationsTable of Hex Codes for Serial Communication VP-1608 Table of Hex Codes for Serial Communication Hex Tables for Audio Input Gain Control Hex Tables for Audio Input/Output Gain ControlInputs Hex Tables for Audio Output Gain Control VP-1608 Hex Tables for Audio Input/Output Gain Control Machine Number Kramer ProtocolVP-1608 Kramer Protocol Load Video Data VP-1608 Kramer Protocol Page 2900