Delta MCS 1800 3U
Power Shelf
Installation, Operations and
Maintenance Manual
DELTA ELECTRONICS, INC.
Page 1
Page 3
Image 2
Page 1
Page 3
Contents
Delta MCS-1800 Power Shelf
Delta MCS 1800 3U Power Shelf
Table of Contents
Maintenance
System Start -Up Procedure
System Alarms and Troubleshooting
Acronyms and Abbreviations
Using This Manual
General
Product Description
Product Main Features
System Specifications
Specification Value
Environmental Data
Electrical Data
Input
Status/Alarm Indicators
Output
Mechanical Data Dimension Value
Description
Power Supply Unit PSU
Specifications
Electrical
Protection
Condition Response
Environmental
Adjustments
Adjustment Description
Operation and Adjustment
Current Limit Setting
System Alarm
PSU Block Diagram
PSU Operating Principle
Characteristic Value
Alarm Control Unit
Input Characteristics
Input Voltage Range Output
Voltage/Current
Settings Description
Indicators
Relay Output
ALU Alarm Signal Descriptions
Physical
Alarm Control Unit Block Diagram
Settings and Control
AC Low Voltage Alarm
Settings Description Comment
AC High Voltage Alarm
Temperature Alarm
Hvsd Recovery
Temperature Shut Down
Control Settings Description Comment Remote SMR On/Off
Floating / Equalize control
DC Distribution
Low Voltage Battery Disconnect System equipped with PDU
Battery Connections System equipped with PDU
DC Cabling
Installation
AC High Voltage Aux. Relay output wiring
Temperature and Alarm Connections
Signal I/P connector
System Start-Up Procedure
High Voltage Shutdown Alarm
System Alarms and Troubleshooting
AC Fail Voltage Alarm Description
High Voltage Alarm Description
Fuse/Circuit Breaker Fail Alarm System equipped with PDU
Low Voltage Alarm
Low Voltage Disconnect Alarm System equipped with PDU
Alarm Unit Fail
Rectifier Fail Alarm
Removing and Replacing a Rectifier Unit
Maintenance
Cleaning and Maintenance
Acronyms and Abbreviations
Cispr
10-2
10-3
Attachment
ES 48/120-JAAxx、ES 24/200-JAAxx -48V/+24VPower Shelf
PDU
Delta MCS 1800 3U Power Shelf
Alarm Relay Output
4ES 48/120-JAAxx Shelf Wiring MCS 1800 Series Shelf
5ES 24/200-JAAxx Shelf Wiring Diagram
ES 48/90-JBAxx -48V Power Shelf With PDU
ES 48/90-JBAxx DC Output Lug Distribution
Delta MCS 1800 3U Power Shelf
台達電子工業股份有限公司 交換式電源供應器
ES 48/90-JBAxx Battery and Load Breaker Distribution
ES 48/90-JBAxx Shelf Wiring MCS 1800 Series Shelf
ES 48/90-JFAxx -48V Power Shelf With PDU
ES 48/90-JFAxx Alarm Relay Output connectors
ES 48/90-JFAxx AC Input Connector
ES 48/90-JFAxx Battery Temperature
ES 48/90-JFAxx DC Output Lug Distribution
ES 48/90-JFAxx Shelf Wiring MCS 1800 Series Shelf
Alarm Control Unit
SMR RFA
Power Supply Unit
Eeprom
SMR Block Diagram
TEL -3-4526107P/N MCS-1800 Power Shelf
Related pages
All Power page
Power Management for Acer VD.T39V1.001
Power Management for Intel AI5VG
Power on Self Test Messages for Fujitsu P7230
FAN Power Headers SYSFAN1, SYSFAN2 3-pin, Cpufan 4-pin for AMD KM780V
Tryck på knappen POWER. Menyn Home visas for Samsung BD-C5500/XEE
Do not insert the power plug with wet hands for Samsung RT58WASM1/BUL
Power On/Off Switch for KitchenAid BUILT-IN REFRIGERATOR
Função Power Zone for Tefal GV8925C0
Check Power Supply Fuse for Maytag ACO1520AW
Power Supply for Polaroid PDV-0823A
What languages are supported in the Subtitle settings of the
Marantz DV7001
?
Top
Page
Image
Contents