Delta Electronics 3KVA, 700VA manual Intelligent design, Considerate design, Green function design

Page 8

Intelligent design

Integrated with a microprocessor, the UPS is able to perform intelligent functions. The UPS triggers over-voltage protection function and transfers to “On- Battery mode” even when utility voltage exceeds 300V for 200V-series. In addition, the UPS can accept large voltage variation of 65V to 138V for 100V-series or 130V to 275V for 200V-series. Wide input voltage range means less battery power usage frequency and longer battery life-span. Besides, programmable outlet design, suitable for power management, is also included in this unit.

Considerate design

Battery start function allows startup of the UPS even when there is no AC line available. In addition, the UPS which was shut down by remote control during power line blackout will restart automatically when AC power recovers. Using our automatic frequency sensing function to match input and output frequency, users don't need to set either 50Hz or 60Hz. Other features, such as UPS self-diagnosis and flexible external battery pack, are also included.

Green function design

The UPS comes with an intelligent fan design, which can have variable fan speed depending on load status, thereby saving the use of power and reducing audible noise. Besides, the operation in sleeping mode is designed to just keep charging which saves the energy a lot.

User friendly interface

The UPS provides a variety of functions which meet users’ needs. Users can instantly understand the status of the UPS via the informative LED display. Audible alarms, bar meters and status indicators, such as battery replace indication, UPS fault, line condition, overload etc. are simple and easy for user to understand. Moreover, users can simply reset the circuit breaker instead of having to replace a fuse in the event of output overload.

Safety approvals

The UPS has passed various safety regulations. UL/cUL, TUV/EMC, TUV/GS, CE mark and other safety approvals, proves that the UPS is a safe reliable solution to your power problems.

Network Management

Build-in communication interface port supporting RS232 and Dry contact protocols enhances the reliability and manageability of the UPS over all major operating systems, including Windows 95/98, Windows NT, Netware, Unix, and others. Besides, the UPS also supports the Simple Network Management Protocol and Hyper Text Transfer Protocol via plugging a SNMP/HTTP adapter into the build-in SNMP slot.

7

SHEET 8 TO 9

Image 8
Contents Sheet 1 to Important Safety Instructions UL safety instructionsOther safety notes Other safety instructions TUV safety instructionsFor installation EC conformity declaration Introduction Theory of operationFeature High power densityPFC Power Factor Correction Complete ProtectionSafety approvals Intelligent designConsiderate design Green function designAnnotation and symbol Read before OperationOperation Panel Sheet 11 to Rear Panel Sheet 13 to Installation Before InstallationInstallation Unpacking If input type is terminal type UPSCharging the battery Connecting the battery bankConnecting the RS-232/Dry contact Sheet 18 to Cold start when utility is not present OperationTurning on the UPS Turning OFF the UPSUPS self-test Silence functionSheet 21 to UPS internal fault Derating powerStoring the message into Eeprom Programmable output OptionalMaintenance Placement Troubleshooting Problem Possible Cause SolutionFault Message Communication Interface RS-232Dry Contact Sheet 29 to Technical specifications Sheet 31 to END