Chapter 1. Product Overview
Table 1–2 Shelf Technical Specifications (continued)
Feature
Regulatory approvals
Description
EMI/R I
Safety
22.2#950,1995, EN60950/A3:1995, VDE 0905, TUV, GS Mark, CE mark
Table 1–3 Controller Shelf Power and Physical Specifications
Operating Environment
Power required
Temperature
Relative humidity – optimal Relative humidity – minimum required
Altitude
Inlet air volume
Air quality
Temperature
Relative humidity
Altitude
Specification
18 to 24° C ( 65 to 75° F)
10 to 40° C (50 to 104° F )
40% to 60% non condensing
10% to 90% non condensing
Maximum wet bulb temperature 28o C (82o F) Minimum dew point: 2o C (36o F)
Up to 8,000 ft (2,400 m)
0.026 cubic meter per second (50 cubic feet per mi- nute)
Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger
8% to 95% non condensing in original shipping con- tainer
From
Physical Characteristics1
-Height
-Width
-Depth
-Weight
Installed Dimensions
Controller and disk shelves
150 mm (5.9 in) /4 U
445 mm (17.5 in)
350 mm (13.8 in)
Controller shelf 9.5kg (21 lbs.)
Disk shelf 7.3 kg.(16 lbs.)
UPS
8.9mm (3.5 in) /2U
48.2mm (19 in)
40.6mm (16.0 in)
UPS 27kg (58 lbs.)
(1) Disk SBBs not included