RAID Array 3000 Storage Subsystem
Figure 4-9. Restored Configuration Example
NOTE
Restoring the configuration in the following step may take up to 5 minutes. Be patient.
4.Enter the file name that you saved in Section 4.2.1 and click on Restore.
4.2.7Update Firmware on Second Controller
1.After configuration has been restored, update firmware on the second controller. Repeat the procedure in Section 4.2.2.1 or 4.2.2.2.
2.After the configuration has been restored and firmware has been updated, power down the system.
4.2.8Install Original Controller
1.If installing option kit
2.Install the second controller into the controller shelf and power up the system. The system is now in the
3.Locate the second serial cable that came in the second controller kit. Connect this cable to the second controller serial port on the RA3000 and to COM 2 port and restart SWCC in serial mode. You now have two serial connections.
4.To check that the controller pair is in redundant mode, click on the Controller icon. Properties for both controllers should be visible. Firmware revision of both controllers must be identical. If either controller is shown in gray, refer to your RA3000 Getting Started Guide for more detailed instructions.