Lamp information
Calculation of lamp hour
When the projector is in operation, the duration (in hours) of lamp usage is automatically calculated by the
Total (equivalent) lamp hour
= 1 (hours used in Economic mode) + 3/2 (hours used in normal mode)
See "Lamp mode (Normal)" on page 47 for more information on Economic mode.
The lamp hour in Economic mode is calculated as 2/3 of that in normal mode. That is, using the projector in Economic mode helps to extend the lamp hour by 1/2.
Warning message
When the Lamp indicator lights up red or a message appears suggesting it is time to replace the lamp, please install a new lamp or consult your dealer. An old lamp may cause a malfunction in the projector and in some instances the lamp may explode.
The Lamp indicator light and Temperature warning light will light up if the lamp becomes too hot. Turn the power off and let the projector cool for 45 minutes. If the Lamp or Temp indicator still lights up after turning the power back on, please contact your dealer. See "Indicators" on page 54 for details.
The following Lamp warning displays will remind you to change the lamp.
Message | Status | |
Notice | The lamp has been in operation for 2000 hours. | |
Install a new lamp for optimal performance. If the | ||
| ||
Order Replacement Lamp | projector is normally run with "Economic Mode" | |
Lamp > 2000 Hours | selected (See "Lamp mode (Normal)" on page 47), | |
you may continue to operate the projector until the | ||
| ||
| 2950 hour lamp warning appears. | |
OK |
| |
|
| |
Notice | The lamp has been in operation for 2950 hours. A | |
new lamp should be fitted to avoid the | ||
| ||
Replace Lamp Soon | inconvenience when the projector runs out of lamp | |
Lamp > 2950 Hours | time. | |
| ||
OK |
| |
|
| |
| The lamp has been in operation for 3000 hours. | |
Notice | It is strongly recommended that you replace the | |
| ||
Replace Lamp Now | lamp at this age. The lamp is a consumable item. | |
Lamp > 3000 Hours | The lamp brightness diminishes with use. This is | |
normal lamp behavior. You can replace the lamp | ||
Lamp usage time exceeded | ||
whenever you notice that the brightness level has | ||
| ||
OK | significantly diminished. If the lamp is not | |
| replaced beforehand, it must be replaced after 3000 | |
| hours usage. | |
|
|
50 Maintenance