Power Supply Specification
1. Input Power Specification
| Specification |
|
|
| Description |
| ||
Input Voltage Range |
| The unit shall meet all the operating requirements with the range | ||||||
| 90 ~ 264 VAC |
|
|
| ||||
|
|
|
|
|
|
| ||
Frequency Range |
| The unit shall meet all the operating requirements with an input | ||||||
| frequency range 47 Hz ~ 63 Hz |
| ||||||
|
|
|
|
| ||||
|
|
|
| Normal operation: 352W (Max) |
| |||
Power Consumption |
| standby mode: < 1W, at 100 ~ 240VAC, monitor out function off, | ||||||
|
|
|
| LAN function off, 12V outlet off |
| |||
Regulation Efficiency |
| 80 % (typical) measuring at 115Vac and full load | ||||||
2. Output Power Requirement |
|
|
| |||||
The power supply can provide DC output as below: |
| |||||||
|
|
|
|
|
|
|
| |
NO. |
| Voltage | Regulation |
| Load Current Range |
| Ripple & Noise | |
1 |
| +12 V |
| 10 % |
| 0 A ~ 2 A |
| 240 mV |
2 |
| +5V |
| 5 % |
| 0.03 ~ 0.1A |
| 100mV |
3 |
| +380V | 370~400 |
| 0.2A |
| 25V |
3.Lamp Power specifications
SpecificationDescription
Applicable Lamp |
| Nor: 230W, Eco: 170W, AC operation |
Starting pulse from Ignitor 2.1KV Min. | ||
4. Power Protection |
|
|
Item |
| Criteria |
Short protection |
| No damage |
OVP |
| 5V: 6 ~6.5V, 12V: 13 ~16V, 380V: 450 ~490V <30ms |
OPP |
| |
5. Surge test: Meet | ||
L N 1KV, L, N | PE 2KV, Criteria B |
6.Electrical Fast Transients (EFT):Meet
7.Voltage Dips: Meet
0% 250 cycle; 40%, 70% reduction 5 cycle, no damage
8.Harmonic current test: Meet