| START UP PROCEDURE |
|
|
|
|
|
Prior to start of operation, follow the procedure below. As for detail of procedure, see the
Determine system configuration
(1)Setting of transfer specification (D8120)
•Specification of data length
•Specification of parity
•Specification of stop bit
•Specification of transfer speed (baud rate)
•Specification of sum check
• S p e c i f i c a t i o n o f t r a n s f e r procedure (exclusive protocol)
(2)Setting of station number (D8120)
(3)Setting of
Creation of program at computer side
······ See section 1.2.
······ For each item of the communication format e. g., station number, time-
out check time, please see the
When using the FX0N series PC, be sure to turn on the special auxiliary
relay M8120 because special data registers D8120, D8121, and D8129
are reserved.
When the special auxiliary relay M8120 is in an ON state, it must be
noted that the backed up data registers D254, D255 become general
data registers.
······ Create communication program on the computer by using BASIC or the similar programming tools.
External wiring
Connection of terminal end resistance
Loop test
Creation of sequence program for data transmission and reception
······ See section 2.1 and 2.2.
······ See section 2.3.
······ Execute loop test, and confirm data exchange. For details see the
······ When using
Operation