PLUS Vision U2-1130/U2-1110 Installation c o n t i n u e d, Using the ceiling mounting fixtures

Page 12

I n s t a l l a t i o n ( c o n t i n u e d )

• Projecting distance and image size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Projection distance

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

11

12 (m)

 

 

0

3.3

6.6

9.8

13.1

16.4

19.7

23.0

26.2

29.5

32.8

36.1

39.4 (feet)

 

 

Tele. – Wide

 

 

 

 

12.3m / 40.4 feet

 

 

 

 

Height of the

 

250– 300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagonal

200– 240

3.9m / 12.8 feet

9.8m / 32.2 feet

 

 

 

 

 

projecting image

 

 

wide mode

 

 

 

 

5m

/ 16.4 feet

 

 

 

4.9m / 16.1 feet

 

 

 

 

 

 

 

6m

/ 19.7 feet

 

100– 120

 

 

 

 

 

Image center in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

image

80– 96

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

2.9m / 9.5 feet

 

 

 

Image center

 

 

 

4m

/ 13.1 feet

 

60– 72

 

 

 

in telephoto

 

 

 

 

 

 

 

 

 

 

 

 

size

1.9m / 6.2 feet

 

 

 

 

 

 

 

 

 

3m

/ 9.8feet

40– 48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(inch)

25– 30

1.2m

 

 

 

 

 

 

 

 

 

 

2m

/ 6.6 feet

 

 

 

 

 

 

 

 

 

 

 

 

3.9 feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.1˚ – 14.5˚

1m

/ 3.3 feet

 

 

 

 

 

 

 

 

12.7˚ – 12.1˚

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0m

/ 0 feet

Center of lens

Using the ceiling mounting fixtures

When using the ceiling hanging fixtures, select “FRONT/CEILING” in “PROJECTION” of “SETTING MENU” (see pages 17 and 24).

Note

Installing the unit on the ceiling must be performed by qualified PLUS service personnel. Contact your PLUS dealer for more information. Never attempt to install the unit yourself.

Height of the

Projection distance

0

1

2

3

4

5

6

7

8

9

10

11

12 (m)

0

3.3

6.6

9.8

13.1

16.4

19.7

23.0

26.2

29.5

32.8

36.1

39.4 (feet)

projecting image

1m / 3.3 feet

2m / 6.6 feet

3m / 9.8feet

4m / 13.1 feet

5m / 16.4 feet

6m / 19.7 feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2m /

3.9 feet

30)

 

 

 

 

 

 

 

 

 

 

 

 

 

(25 to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.9m / 6.2 fe

 

 

t

 

 

 

 

 

 

 

 

 

e

 

48)

 

 

 

 

 

 

 

 

 

 

 

 

 

(40 to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.9m / 9.5 feet

 

 

 

 

 

2)

 

(60 to

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.9m / 12.8 feet

 

 

 

 

 

 

(80 to

96)

 

 

 

 

4.9m / 16.1 feet

 

 

 

 

 

 

 

 

(100 to 120)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.8m / 32.2 feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12.3m / 40.4 feet

Center of lens

151 to 154 mm/ 0.5 feet

In telephoto mode 4,712 to 4,742 mm/ 15.5 to 15.6 feet

In wide mode 5,613 to 5,660 mm/

(200 to 240) 18.4 to 18.6 feet

(250 to 300)

E – 10

Image 12
Contents U2-1130/U2-1110 Plus Corporation U2-1130/U2-1110 English Precautions Important SafeguardsInstallation Power SupplyB l e o f c o n t e n t s Power cable mains lead 1.8 m/5.9 ft A t u r e sE c k i n g t h e P p l i e d a c c e s s o r i e s Serial mouse cable Mouse adapter For IBM PS/2Remote control effective range E p a r i n g t h e M o t e c o n t r o lInserting the batteries RGB in connector R t s a n d c o n t r o l sTop, front and side panel view Menu buttonLamp cover securing screw Rear adjuster Rear and side panel viewBottom Built-in Security SlotClick button 14 Freeze button Mute buttonInstallation Positioning the unitProjecting distance and image size ScreenInstallation c o n t i n u e d Using the ceiling mounting fixturesUnits terminal panel N n e c t i o n sBefore connecting ConnectorN n e c t i n g a P C o r M a c i n t o s h Modifying the DIP switch setting for Macintosh 3 4 5How does the remote control operate the computer? Connecting the computer to the Mouse connector of the unitHow to connect to the IBM PC/AT computer How to connect to the IBM PS/2 or Macintosh computerAdjust the position and height of the unit I n g t h e u n i tBefore starting View from the topAdjust the image size with the zoom ring Then adjust the focus with the focus ringI n g t h e u n i t c o n t i n u e d After using the unit AmberWindows 98/Windows WindowsMacintosh Adjusting the volume of the units speaker Using the laser pointerTurning off the image and muting the sound temporarily Freezing a moving pictureEnlarging the picture Press PointerPress Magnify + Press MagnifyPointer When the input source is Video or S-VIDEO N u s t r u c t u r eOperating using the unit R r e c t i n g t h e Y s t o n i n g e f f e c t L e c t i n g a m e n u l a n g u a g eL e c t i n g a O j e c t i o n t y p e L e c t i n g t h e c o l o r s y s t e mL e c t i n g t h e p o i n t e r t y p e L e c t i n g t h e b a c k g r o u n dJ u s t i n g t h e v o l u m e Timing Chart Setting the input source to RGB Setting Auto Mode to OFF for manual ad- justmentAdjusting the clock frequency Adjusting the clock phaseJ u s t i n g t h e C t u r e e l e m e n t s L e c t i n g t h e p i c t u r e t y p eT i v a t i n g t h e p o w e r s a v i n g f u n c t i o n T i v a t i n g t h e o n s c r e e n f u n c t i o nI c k s t a r t i n g t h e u n i t Resetting the lamp usage hours to zero E c k i n g h o u r s o f l a m p u s a g eS e t t i n g t o t h e f a c t o r y s e t t i n g s Troubleshooting Common Problems & SolutionsStatus indicator Status Light MessagesLamp cartridge replacement procedure P l a c i n g t h e l a m p c a r t r i d g eStep Specification s OpticalSub Pin Assignments PC 15-Pin mini D-SubDimensions U2-1130U2-1110 Plus Corporation