15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor. Note that this command can be accepted only when PRO is selected from COLOR TEMP.
Transmission Data
DFH 80H 60H 7FH 04H | DATA00 to DATA03 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | GREEN Gain Flag | 02H | |
DATA02: | GREEN Gain 1 (Bias) | D8H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
DATA03: | GREEN Gain2 (Drive) | D8H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
ACK |
|
|
|
|
| ||
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | GREEN Gain Flag | 02H |
16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor. Note that this command can be accepted only when PRO is selected from COLOR TEMP.
Transmission Data
DFH 80H 60H 7FH 04H | DATA00 to DATA03 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | BLUE Gain Flag | 03H | |
DATA02: | BLUE Gain1(Bias) | ||
|
|
|
|
|
| ||
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
DATA03: | BLUE Gain2(Drive) | D8H: | |
|
|
|
|
|
| ||
|
| 00H: 0 | |
|
|
|
|
|
| IEH:+30 | |
ACK |
|
|
|
|
| ||
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | BLUE Gain Flag | 03H |
17. NR MODE Set
Function
The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor.
Transmission Data
DFH 80H 60H C0H 01H DATA00 CKS
DATA00: 01H: NR OFF 02H:
03H:
04H:
ACK
7FH 60H 80H C0H 01H DATA00 CKS
DATA00: 01H: NR OFF 02H:
03H:
04H:
18. BASS Gain Data
Function
The external control equipment changes the BASS gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H | DATA00 DATA01 DATA02 CKS | ||
DATA00: | USER PICTURE Gain Flag | 05H | |
DATA01: | BASS Gain Flag | 03H | |
DATA02: | BASS Gain | F3H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
| 01H: +01 | |
|
|
|
|
|
| 0DH: +13 | |
ACK |
|
|
|
|
|
| |
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: | USER PICTURE Gain Flag | 05H | |
DATA01: | BASS Gain Flag | 03H |
19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
| DFH 80H 60H 7FH 03H | DATA00 DATA01 DATA02 CKS | ||
| DATA00: | USER PICTURE Gain Flag | 05H | |
| DATA01: | TREBLE Gain Flag | 04H | |
| DATA02: | TREBLE Gain | F3H: | |
|
|
|
|
|
|
|
| FFH: | |
|
|
| 00H: 0 | |
|
|
| 01H: +01 | |
|
|
|
|
|
|
|
| 0DH: +13 | |
| ACK |
|
|
|
|
|
|
|
|
| 7FH | 60H 80H 7FH 02H | DATA00 DATA01 CKS | |
45 | DATA00: | USER PICTURE Gain Flag | 05H | |
| DATA01: | TREBLE Gain Flag | 04H |