30. OSM ADJ. Gain Data
Function
The external control equipment sets the position of the OSM menu of the plasma monitor.
Transmission Data
DFH | 80H | 60H | 1AH | 02H | DATA00 DATA01 CKS | |
DATA00: | OSM ADJ. Gain Flag | 02H | ||||
DATA01: | 01H: 1 |
|
|
| ||
|
|
|
|
|
| |
| 09H: 9 |
|
|
| ||
ACK |
|
|
|
|
|
|
|
|
|
|
|
|
|
7FH | 60H | 80H | 1AH | 01H | DATA00 CKS | |
DATA00: | OSM ADJ. Gain Flag | 02H |
31. POWER MGT Select
Function
The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor.
Transmission Data
DFH | 80H | 60H | 1AH | 02H | DATA00 DATA01 CKS |
DATA00: | POWER MGT Select |
| 03H | ||
DATA01: | 01H: ON |
|
|
| |
| 02H: OFF |
|
|
| |
ACK |
|
|
|
|
|
|
|
|
|
|
|
7FH | 60H | 80H | 1AH | 02H | DATA00 DATA01 CKS |
DATA00: | POWER MGT Select |
| 03H | ||
DATA01: | 01H: ON |
|
|
| |
| 02H: OFF |
|
|
|
32. GRAY LEVEL Set
Function
The external control equipment sets the GRAY LEVEL of the plasma monitor.
Transmission Data
DFH | 80H | 60H | C6H 01H | DATA00 CKS | |
DATA00: | GRAY LEVEL | 00H: 0 | |||
|
|
|
|
|
|
|
|
|
| 0FH: 15 | |
ACK |
|
|
|
|
|
|
|
|
|
|
|
7FH | 60H | 80H | C6H 01H | DATA00 CKS | |
DATA00: | GRAY LEVEL | 00H: 0 | |||
|
|
|
|
|
|
|
|
|
| 0FH: 15 |
33. CINEMA MODE Set
Function
The external control equipment switches on or off the CINEMA MODE of the plasma monitor.
Transmission Data
DFH | 80H | 60H | C1H 01H | DATA00 CKS |
DATA00: | CINEMA MODE Set | 01H: ON | ||
|
|
|
| 02H: OFF |
ACK |
|
|
|
|
|
|
|
|
|
7FH | 60H | 80H | C1H 01H | DATA00 CKS |
DATA00: | CINEMA MODE Set | 01H: ON | ||
|
|
|
| 02H: OFF |
34. RGB3 ADJ. Select
Function
The external control equipment sets the RGB3 ADJUST of the plasma monitor.
Transmission Data |
|
|
| ||
DFH | 80H | 60H | 1AH | 02H | DATA00 DATA01 CKS |
DATA00: | RGB3 ADJ. Select |
| 06H | ||
DATA01: | 01H: 1 |
|
|
| |
| 02H: 2 |
|
|
| |
| 03H: 3 |
|
|
| |
ACK |
|
|
|
|
|
|
|
|
|
|
|
7FH | 60H | 80H | 1AH | 02H | DATA00 DATA01 CKS |
DATA00: | RGB3 ADJ. Select |
| 06H | ||
DATA01: | 01H: 1 |
|
|
| |
| 02H: 2 |
|
|
| |
| 03H: 3 |
|
|
|
35. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) of the plasma monitor.
Transmission Data |
| |
DFH 80H 60H 6BH 03H | DATA00 DATA01 DATA02 CKS | |
DATA00: | PLE | 01H: AUTO |
|
| 02H: LOCK |
DATA01: | INVERSE | 01H: ON |
|
| 02H: OFF |
|
| 03H: WHITE |
DATA02: | ORBITER (PICTURE SHIFT) | 01H: ON |
|
| 02H: OFF |
ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness):
3FH 60H 80H 6BH 00H CKS
48