JVC GD-V501PCE Serial Terminals connection, Installing the ferrite core, Communication parameters

Page 11

Connections

SERIAL Terminals connection

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

RS-232C

Ferrite core

 

(large size)

 

SERIAL

straight cable

(supplied)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-sub 9p

Less than

3" 15/16

 

 

(10 cm)

Notes:

(1)Use the RS-232C cable to connect the computer to the Plasma Display.

(2)The computer shown is for example purposes only.

(3)Additional equipment and cables shown are not supplied with this set.

6 7 8 9

1 2 3 4 5

Pin layout for RS-232C

Installing the ferrite core

(Large size)

Open

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details.

Communication parameters

Signal level

RS-232C compliant

Synchronization method

Asynchronous

 

 

Baud rate

9600 bps

 

 

Parity

None

Character length

8 bits

 

 

Stop bit

1 bit

 

 

Flow control

-

 

 

 

RS-232C Conversion cable

D-sub 9-pin female

Details

2

 

R X D

3

 

T X D

5

 

GND

4 •

6

Non use

7

 

Shorted

8

 

 

 

1 •

9

NC

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX

 

 

 

 

Colon

 

Parameter(s)

 

End

 

 

 

 

 

 

Start

 

3-character

(1 - 5 bytes)

 

(03h)

 

 

(02h)

 

command (3bytes)

 

 

 

Notes:

(1)If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

(2)If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

AMT

0

Audio mute OFF

1

Audio mute ON

 

IIS

None

Input select (toggle)

(When Used

VID

AV Mode

VIDEO

YP1

Component / RGB mode (processed as a

INPUT

 

Y/PB/PR or RGB signals as set by this unit)

CARD)

RG1

PC Mode

DAM

None

Screen mode select (toggle)

 

NORM

4 : 3

 

ZOOM

Zoom

 

FULL

16 : 9

 

JUST

Just

 

SELF

Auto

With the power off, this display responds to PON command only.

11

Image 11
Contents Plasma Display Monitor GD-V501PCEINSTRUCTIONS Table of Contents Trademark Credits Important Safety NoticeFor UK only Important the Moulded Plug Important Safety NoticeWhen using the Plasma Display Safety PrecautionsSetup If problems occur during use Cleaning and maintenanceSafety Precautions Check that you have the accessories and items shown AccessoriesAccessories Supply Optional AccessoriesHelpful Hint Remote Control BatteriesPrecaution on battery use Observe the following precautionCable fixing bands ConnectionsPC Input Terminals connection Installing the ferrite core Small sizeInstalling the ferrite core Large size Signal Names for D-sub 15P ConnectorCommunication parameters Installing the ferrite coreCommand Serial Terminals connectionBasic Controls Basic Controls Input button AVS Video, Component/RGB and PC Mode SelectionSound mute On/Off see Volume Adjustment OFF Timer buttonAC cord connection Power On/Off and input signal selectionPower On/Off Connecting the plug to the Wall OutletSelecting the On-Screen Menu Language Select the input signalPower On/Off and input signal selection To Picture adjust menu Press to select each item See On-Screen Menu Display from Remote ControlSee page 30 Component see To Signal screen for PC see On-Screen Menu Display from Remote ControlAspect Controls Auto Aspect ControlsZoom JustAdjusting screen Adjusting Picture Pos./SizePos Adjusting Picture Pos./SizeSize Clock Phase RGB/PC in Mode Helpful Hint N / Normalise NormalisationTreble Sound AdjustmentMute BassSurround Surround Button Surround ControlsOn Off Cinema Picture AdjustmentsNormal DynamicPicture Adjustments Advanced SettingsPresent Time Set Set up TimerSetup Timer Timer SetTo stop the Screensaver under On, press the button Mode selectionScreensaver For preventing after-images Reversal / Scroll selectionScreensaver For preventing after-images Setup of Screensaver TimeSide Panel Adjustment 3D Y/C Filter For Ntsc AV images Setup for Input SignalsComponent/RGB-in Select If the picture image becomes unstable Setup for Input SignalsColour system / Aspect Auto PulldownFreq. kHz/V-Freq. Hz Setup for input signals SyncSetting RGB sync signal Setting PC sync signalPlasma Display panel Symptoms Check TroubleshootingPC RGB input AV input signalsComponent /RGB/PC input signals Connection to the Optional Video Input Card. IF-C50P1GVideo 4 pin socket Video signal connectionAV Input Terminals connection AV Out Component/RGB Input connection Component signals Y, PB, PR connectionRGB signal R, G, B, HD, VD connection Specifications Optional Supplied SpecificationsDimensions Mass WeightGD-V501PCE Plasma Display Monitor