Power Wash 250™
3.10.10 Feedback (FEED)
FEED
The POWER WASH 250B™ is equipped with ”APC,” automatic position correction. This function automatically corrects the Pan and Tilt movement should the unit lose step or is obstructed and forced to lose step. Press the Enter button to access the
3.10.11 Correction of faults (EFLD)
EFLG
(These functions are reserved for authorized technicians only)
3.11 Error and Information Messages
HEAt This message appears if you try to switch on the lamp within 5 minutes after having switched off (lamp too hot). The message will appear on the display if the lamp doesn’t ignite within 20 seconds. The fixture will store this command and automatically ignite the lamp after 5 minutes.
LaeR After two unsuccessful lamp ignition attempts the display will readout LAER. This means the lamp could be damaged, the lamp is missing, the fixture is overheating, or there could be a failure on the igniter or ballast.
OTMP This error message informs you the fixture was overheating and the protective relay switched off the lamp. Please look for possible reasons (fan faulty, air in/outlets blocked or very dirty, lamp broken or very old, too high ambient temperature. Switch off the power supply and solve the possible problem.
RsER This message informs you one of the fixtures function was unable to reset properly (magnetic sensor, stepping motor, driver on the PCB, cables, etc.). Repair the defect and start the fixture again.
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com | - | Page 24 |