Power Wash 250™
Press Enter to confirm or Mode to cancel and return to the menu.
DON Display On/Off (If you've chosen off, the display will go out within 15 seconds after the last input. The next key touch will reactivate the display).
REV Turn around the display
3.10.6 Fixture Temperature (TEMP)
TEMP
This function allows you to read out the actual fixture operating temperature. Press the Enter button to confirm or the Mode to button to cancel and return to the main menu. Normal operating temperature should
range between 85˚C and 95˚C. Operating temperatures between 96˚C and
104˚C are considered critical. Temperatures above 105°C will send the fixture into protect mode and automatically switch the lamp off, the lamp will remain off until internal temperature drops below 95˚C.
3.10.7 Fan Control (FANS)
FANS
By using this function you can choose between 4 types of fan speed operations. Use the Up and Down buttons to select the desired function and press Enter to confirm or Mode to cancel and return to the menu. The chart below will detail the different fan settings:
| HIGH | The cooling fan works continuously at max. speed. |
|
|
| This is the default fan setting. In this setting an internal thermal |
|
| REG | sensor constantly monitors the internal operating temperature |
|
| and regulates the fan speed to coincide with the internal |
| |
|
|
| |
|
| temperature. |
|
|
| This function is designed for environments that require low |
|
| LOOF | ambient noise. In this setting the fan will operate at the lowest |
|
|
| speed. When the maximum internal intolerable operating |
|
|
| temperature is reached the lamp will automatically shut off. |
|
|
| In this setting the fan will operate at the lowest speed. When the |
|
| LOHI | maximum internal intolerable operating temperature is reached |
|
|
| the fan will automatically switch from low to high speed. |
|