Power Wash 250™
6.2 Removing the Lamp
6.2.1Be sure the unit is disconnected from it’s main power supply.
6.2.2Remove the 3 retaining Phillips screws that secure the lamp cover to fixture chasis.
6.2.3Once the lamp cover is free, expose the lamp by gently pull out the lamp socket assembly.
6.2.4Gently remove the old lamp from it’s socket. If the old lamp has exploded be sure to remove all of the old lamp fragments to prevent damage to the internal components.
6.2.5Replace the lamp with an approved replacement type. Be sure to follow all the lamp handleing procedures included with your new lamp. Never handle the new lamp with your bare hands, the oils from your skin may damage the lamp. Always replace with the lamp with a lamp that meets the orginal lamp specification, failure to do so may damage the unit and will void your manufactures warranty.
6.2.6Before reassembing the unit, be sure to adjust the lamp distance from the main lens. The optimum distance between the lamp and the lens is between
6.2.7Reassemble the unit in reverse order.
6.2.8Besure to reset the lamp running time (see page 19).
Attention:
Be sure the lamp is securely seated in the lamp socket. Also pay close attention to the lamp orientation, optimum distance between the lamp and the lens should range between 1.0 - 1.5 mm. Failure to comply with this warning may cause excessive heat
6.3 Lamp Optimization
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com | - | Page 30 |