Initial configuration

Step one: Configure Ethernet Ports A and B

The default setting for the IP GW blade Ethernet ports is auto-sensing mode. If the switch ports to which you connect the IP GW blade are not also set to auto-sensing mode, then you need to configure the IP GW blade Ethernet ports to use the same speed and duplex mode.

Both ends of the Ethernet connection must be configured in the same

iway. For example, either configure both ends of the link to be auto- sensing or configure both ends to operate at the same speed and duplex.

To establish a 1000Mbps connection, both ends of the link must be

iconfigured as auto-sensing.

You can use the Supervisor’s web interface to configure the IP addresses of all blades installed in the MSE 8000. Note that all blades are supplied with DHCP enabled on Port A; you can either keep this setting or assign static IP address to Port A. Port B does not support DHCP; you must manually configure its IP address.

To configure the IP addresses and port settings of the IP GW blade, log in to the Supervisor and go to Hardware > Blades. To access the web interface of the IP GW blade, go to Hardware > Blades and click the IP address of that blade.

For more information about configuring the ports, refer to the online help accessible from the Supervisor’s web interface.

Step two: Configure the default gateway and routes (optional)

If the networks to which you connect contain more than one subnet, you might need to change the default gateway preference on the IP GW blade (default setting is Port A). You might also need to add routes to the configuration of the IP GW blade to indicate which interface will be used for certain IP addresses.

To configure the default gateway and route information:

1Log in to the Supervisor and go to Hardware > Blades.

2Click the name of the IP GW blade and select the Routes tab.

For more information about route configuration, refer to the online help topic: “Individual blade routes configuration”.

7

Image 11
Contents Codian IP Gateway Codian IP Gateway Tandberg Table of contents Port and LED location General informationAbout the MSE 8350 IP GW blade LED behavior FDX Step one Install the IP GW blade into the MSE 8000 chassis Installing the IP GW bladeInserting a blade into the chassis Step two Connect to Ethernet Ports a and B Step two Configure the default gateway and routes optional Initial configurationStep one Configure Ethernet Ports a and B Step one Log in to the IP GW blade Configuring the IP GW bladeStep four Configure an operator optional Step three Configure the auto attendant menus optionalStep five Add endpoints and call groups optional Step six Configure the dial planChecking for updates Getting more help Troubleshooting and technical support informationUsing the event log to help solve a problem 61-0018-04