When dialing the number 67890000 there will be a match with “0000” as the significant number. The H.323 number to call is: 50000 (construction: prefix + significant numbers + postfix). When dialing number 67894321 this will match with “4321” as the significant number. The H.323 number to call is: 54321 (construction: prefix + significant numbers + postfix)

Example 2: Hotline

Service type DiD

Net type (from): H324m/3G

From Prefix/Nr: 67890000

From Postfix:

Net type (to): H323

To Prefix/Nr: 51234

To Postfix:

When dialing number 67890000 this will match with no significant number. The H.323 number to call is: 51234 (construction: prefix + significant numbers + postfix). When dialing number 67894321 this will not match.

Example3: SIP to H323

Service type DiD

Net type (from): SIP

From Prefix/Nr: 12345

From Postfix:

Net type (to): H323

To Prefix/Nr: 987654321

To Postfix:

When dialing number 12345@<3G-Gateway-IP-Address> on a SIP endpoint, one is connected to an H323 endpoint with number 987654321.

Example4: H323 to SIP

Service type DiD

Net type (from): H323

From Prefix/Nr: 12346

From Postfix:

Net type (to): SIP

To Prefix/Nr: 1234567

To Postfix: @<SIP-Proxy-Address>

When dialing number 12346 on an H323 endpoint, one is connected to 1234567@<SIP-Proxy- Address>

53

Image 53
Contents 3G Gateway TandbergDisclaimer Trademarks and copyrightIii TANDBERG’s Environmental Policy Environmental IssuesOperator Safety Summary Contact us Table of Contents Introduction Network and Features Rear view Tandberg 3G GatewayFront view 1 3G Gateway Capacity typical scenarios Precautions InstallationUnpacking Installation site preparationsPower cable Connecting cablesIsdn PRI or BRI cables LAN cable3G Gateway Configuration 3G Gateway start-up Accessing the 3G GatewayPage Idle No call is active Active Call Call is active Using the 3G Gateway Call OverviewGW Calls Duration Idle No active call, call has been disconnectedStatus IP/H.323Did Dial from UmtsSequence of Services ConnectingDial from IP ServicesPage PRI Status View System StatusIsdn PRI/BRI Status BRI Status Page IP Address Shows the IP address of the 3G Gateway 2 H.323 StatusSystem Information Available Resources Isdn PRI/BRI Configuration Configure the 3G GatewayPRI Configuration PRI ProtocolBearer capabilities BRI configurationLow Channel BRI ProtocolBearer capabilities General SS7 ConfigurationTrunks Link setsExample1 RestartExample2 Page Page IP Address Assignment IP ConfigurationAddress Subnet MaskEthernet Speed Auto Date and Time Settings10Half 10FullGatekeeper IP Address H.323 ConfigurationAuthentication ID, Password Authentication ModeSIP Configuration Video Portal Systems Video Portal ConfigurationVideo Portal Settings Snmp Mode Snmp ConfigurationSnmp Community name System contactSnmp Trap Host 1, 2 System locationPassword Miscellaneous ConfigurationConfiguration Services Phonebook settingsExternal Manager settings Software Upgrade Page Page Service type Services ConfigurationDescription Net type from10.1 IVR Example 1 Number-plan mapping ExamplesBackspace Example4 H323 to SIP Example 2 HotlineExample3 SIP to H323 Appendices Appendix 1 Declaration of Conformity State 1 menu navigation, Display current menu item Appendix 3 using the front panel LCD keysState 7 Choose Configuration option Technical Specifications Index Tandberg Gateway Index Snmp