The BRI status displays the conditions of ISDN layer 1 and 2 separately. Green indicates up and in sync. Red indicates not in sync and indicate probably a disconnected ISDN line.

Besides the indications on the webpage each ISDN BRI interface located at the back-side of the

3G Gateway has a green and orange LED. The meanings of these LEDs are:

Green: Layer 1 of the ISDN signaling is up.

Green and Orange indicates that both layers 1 and 2 are up. Insome countries the orange LED can blinks on a regular interval, or is turned on when there is an active call.

No LEDs light-up indicates that there is no connection or a wrong wired connection.

Note that in some countries layer 2 can be down when there is no activity (ongoing connections). However, layer 2 should become active when a call is made or received.

Note that in case the BRI 3G Gateway is connected with less then 4 BR lines, the BRI interfaces with the highest number(s) should be left open. For example when only 2 ISDN lines are used they should be connected with interface 1 and 2.

26

Image 26
Contents Tandberg 3G GatewayTrademarks and copyright DisclaimerIii Environmental Issues TANDBERG’s Environmental PolicyOperator Safety Summary Contact us Table of Contents Introduction Network and Features Rear view Tandberg 3G GatewayFront view 1 3G Gateway Capacity typical scenarios Installation PrecautionsInstallation site preparations UnpackingIsdn PRI or BRI cables Connecting cablesPower cable LAN cable3G Gateway Configuration Accessing the 3G Gateway 3G Gateway start-upPage Idle No call is active Active Call Call is active Using the 3G Gateway Call OverviewGW Calls Status Idle No active call, call has been disconnectedDuration IP/H.323Dial from Umts DidConnecting Sequence of ServicesServices Dial from IPPage PRI Status View System StatusIsdn PRI/BRI Status BRI Status Page IP Address Shows the IP address of the 3G Gateway 2 H.323 StatusSystem Information Available Resources PRI Configuration Configure the 3G GatewayIsdn PRI/BRI Configuration PRI ProtocolLow Channel BRI configurationBearer capabilities BRI ProtocolBearer capabilities Trunks SS7 ConfigurationGeneral Link setsRestart Example1Example2 Page Page Address IP ConfigurationIP Address Assignment Subnet Mask10Half Date and Time SettingsEthernet Speed Auto 10FullH.323 Configuration Gatekeeper IP AddressAuthentication Mode Authentication ID, PasswordSIP Configuration Video Portal Systems Video Portal ConfigurationVideo Portal Settings Snmp Community name Snmp ConfigurationSnmp Mode System contactSystem location Snmp Trap Host 1, 2Password Miscellaneous ConfigurationConfiguration Services Phonebook settingsExternal Manager settings Software Upgrade Page Page Description Services ConfigurationService type Net type from10.1 IVR Example 1 Number-plan mapping ExamplesBackspace Example4 H323 to SIP Example 2 HotlineExample3 SIP to H323 Appendices Appendix 1 Declaration of Conformity Appendix 3 using the front panel LCD keys State 1 menu navigation, Display current menu itemState 7 Choose Configuration option Technical Specifications Index Tandberg Gateway Index Snmp