Operation

Picture

Picture

Brightness

Contrast

Color

Tint

Sharpness

Use the controls in the Picture Menu to calibrate your VX-2i for optimum picture quality.

The VX-2i has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to obtain optimal picture quality from Runco video display devices. Accordingly, Runco recommends that setup and calibration be performed by an ISF certified installation technician.

All signal types require separate processing. Therefore, you need to calibrate each input separately. Runco recommends calibrating the VX-2i inputs in the following order:

1.Component SD

2.S-Video 1 / S-Video 2

3.Composite

4.HD/RGB 1 / HD/RGB 2

5.DVI 1 / DVI 2

When you change a picture quality setting, save the change to a

Note preset afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for

each input and resolution separately.) For information about saving settings, refer to ISF Presets on page 34.

Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Runco recommends using the following calibration tools for best results:

External test pattern source -- Sencore VP401 Multimedia Video Generator, Ovation Multimedia test DVD or equivalent.

A blue filter (provided with many test DVDs), for color level and tint adjustments.

Connect your test pattern source to the input that you are calibrating and proceed as follows. Perform the adjustments in the order listed here.

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2shows a typical PLUGE pattern.

Below Black

Above Black

Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness

30

Runco VX-2i Owner’s Operating Manual

Image 40
Contents VX-2i Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Runco INTERNATIONAL, INC Safety Precautions Table of Contents Maintenance and Troubleshooting SpecificationsOperation Serial CommunicationsList of Figures List of Figures Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Functions VX-2i at a GlanceComponent Video RCA connectors HD1 / HD2 Analog BNC connectorsVolt 800 mA Trigger Outputs Video 1 / S-VIDEOVX-2i Remote Control Power Input 100 to 240 VAC Connect the VX-2i to power hereOn / OFF Cursor KeysVideo Comp ComponentAspect Ratio Selection Buttons ANA Anamorphic 3 For 169 DVDs 4X3 Standard 43Letbox Letterbox Wide VirtualWideInstallation Remote ControlQuick Setup Step Procedure For Details, Refer toInstallation Considerations Installation TypeFlat vs. Curved Screens Other Considerations Ambient LightThrow Distance Throw Ratio Throw Distance Range Lens Option Note Throw Dist Screen Width Minimum MaximumPosition Vertical and HorizontalLens Shift Vertical Lens Shift Adjusting the Projection AngleMounting Folded OpticsConnector Panel Access Connecting the VX-2i toConnections to VX-2iDigital DTV RGB Connections See Figure Digital DTV RGB ConnectionsAnalog Computer RGB Connections See Figure Analog RGB ConnectionsComposite/S-Video/Component Video Connections See Figure 10. Composite, S-Video and Component Video ConnectionsConnecting 12-Volt RS-232 ControllerConnection Trigger Outputs toAdjusting the Picture Orientation Turning on the PowerOperation Using the On-Screen Menus Lens AdjustmentsFocus Zoom Shift ISF Presets ServiceInput Source Aspect RatioMain Menu Input SourceAspect Ratio Input Source Composite Video Component SDAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanISF Presets InformationCalibration Should be used by ISF-certified technicians onlyOperation Service Tip Operation Lamp Replacement Troubleshooting Tips Maintenance and TroubleshootingSymptom Possible Causes Solution Maintenance and Troubleshooting RS-232 Connection and Port Configuration Serial Command SyntaxCommand Parameter Value Description Min/max Stored? Serial CommunicationsSerial Communications Night YES SHARPNESS? Specifications VX-2i SpecificationsHome Theater Calibration Specifications Industry-Standard SpecificationsPower Requirements DimensionsLimited Warranty Specifications are subject to change without noticeVX-2i Dimensions VX-2i DimensionsPage Runco CL-810 Owner’s Operating Manual