Specifications
Table
Brightness and Contrast: | Cinema Standards Measurement System (CSMS) | |
| Specifications | |
| - | Brightness: 52.1 |
| - | Contrast Ratio: 217:1 |
| These measurements are taken from the projector in a controlled, | |
| home theater environment. All measurements are made to | |
| ANSI/NAPM | |
| ||
| Video Essentials test DVD and a 1.3 gain, | |
| projector is calibrated to a color temperature of 6,500K and has a | |
| minimum of 150 hours of usage. | |
| The | |
| movie theaters to express image brightness at the screen surface. The | |
| Society of Motion Picture and Television Engineers (SMPTE) specifies | |
| 16 fL as the target image brightness for | |
| open gate (without film in the projector). More importantly, today | |
| SMPTE specifies 12 fL as the target image brightness in Digital | |
| Cinema theaters. The | |
| screen size, screen gain and projector light output. | |
| Home Theater Calibration Specifications | |
| - | Light Output: 1227 ANSI Lumens |
| - | Contrast Ratio: 217:1 |
| These specifications are obtained by calibrating the projector as | |
| described above for CSMS measurements. | |
|
| |
| - | Light Output: 2500 ANSI Lumens |
| - | Contrast Ratio: 2800:1 |
| These are typical projector brightness and contrast specifications | |
| found in most companies’ sales literature. Runco includes these | |
| measurements in its literature to allow for direct comparison with other | |
| manufacturers’ projectors. These measurements are typically taken at | |
| 9,000K to 13,000K to get expected performance data when the | |
| projector is used in professional, commercial and industrial displays. | |
|
| |
Lamp: | 275 Watts | |
|
| |
Estimated Lamp Life: | 2000 hours | |
|
| |
Inputs: | (1) Composite; (2) | |
| (Y), B (Pb), H, V; (2) DVI w/HDCP | |
|
|
|
Control Options: | - | |
| - | Discrete infrared remote |
| - | Serial commands via |
|
| |
Trigger Outputs: | 3 x 12 VDC, 800 mA | |
|
| |
Bandwidth: | 150 Mega Samples/Second (MSPS) | |
|
| |
Power Requirements: | 100 to 240 VAC | |
|
| |
Operating Environment: | 41°F to 95°F (5°C to 35°C), 0% to 90% humidity | |
| ||
|
| |
Dimensions: | See Figure | |
|
| |
Weight (without lens): | 65 lbs. (29.48 kg) | |
|
| |
Regulatory Approvals: | Complies with FCC, CE | |
|
|
|