Sharp PG-D2510X appendix Regarding the Lamp, Replacing the Lamp

Page 58

Regarding the Lamp

Lamp

It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes 5% or less, or when you notice a signifi cant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display. (See page 52.)

Purchase a replacement lamp of type AN-D350LP from your place of purchase, nearest Sharp Authorized Projector Dealer or Service Center.

IMPORTANT NOTE TO U.S. CUSTOMERS:

The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized Projector Dealer or Service Center. For the name of the nearest Sharp Authorized Projector Dealer or Service Center, please call toll-free: 1-888-GO-SHARP (1-888-467-4277).

Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information

www.lamprecycle.org or 1-800-BE-SHARP

U.S.A ONLY

Caution Concerning the Lamp

This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface scratches or deterioration of the lamp due to a lapse of usage time.

The period of time up to failure largely varies depending on the individual lamp and/or the condition and the frequency of use. It is important to note that failure can often result in the bulb cracking.

When the lamp replacement indicator and on-screen display icon are illuminated, it is recommended that the lamp be replaced with a new one immediately, even if the lamp appears to be operating normally.

Should the lamp break, there is also a possibility that glass particles may spread inside of the projector. In such a case, it is recommended you contact your nearest Sharp Authorized Projector Dealer or Service Center to assure safe operation.

Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In case of exposure to the gas, consult a doctor as soon as possible.

Replacing the Lamp

Caution

Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burns or injury.

Wait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool before removing the lamp unit.

Carefully change the lamp by following the instructions described in this section.

* If you wish, you may have the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service Center.

*If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized Projector Dealer or Service Center for repair.

56

Image 58
Contents PG-D2510X Model No Serial No See bottom of projector Void the users authority to operate this equipmentInformation Product Disposal Maintenance Troubleshooting Index For Future ReferenceContents Adjusting the Projector Function PRJ-ADJ1/2 Menu ReferenceAccessories CleaningPower Sources Power-Cord ProtectionSafety Check Damage Requiring ServiceReplacement Parts OverloadingRest your eyes occasionally Avoid locations with extremes of temperatureDo not block the exhaust and intake vents Temperature monitor function Using the projector in other countriesOther connected equipment Page Accessories Optional accessoriesPart Names and Functions Front ViewRear View Terminals Picture Mode button VOL +/- Volume buttonsBreak Timer button CLICK/EFFECT button 34Inserting the Batteries Remote control signal transmittersUsable Range Setup and Projection Easy StartTurn the computer on Turn the power off Setting Up the Projector Setting Up the ProjectorStandard Setup Front Projection Screen Size and Projection Distance Signal Input Normal ModeSignal Input 169 Mode Screen Lens centerProjection PRJ Mode Ceiling-Mount SetupConnecting the Projector to Other Equipment Terminals on the ProjectorConnecting the Projector to Other Equipment RGB AC socket Power cord To AC outlet supplied Connecting the Power CordControlling the Projector by a Computer Turning the Projector On/Off Power indicator Lamp indicatorTurning the Projector On Press Enter to exit the Setup Guide screen About the Setup GuideAdjusting the Projected Image Adjusting the Focus Image ProjectionUse the rear adjustment foot to make the projector level Adjusting the HeightAdjusting the Picture Size Make small adjustments Height Adjust leverCorrecting Trapezoidal Distortion Press Keystone to enter the Keystone Correction modePress P/Q or O/R to adjust Keystone Correction Press KeystoneAdjusting the Volume Switching the Input ModeInput buttons AV Mute button VOL +/- Volume buttons Buttons Resize Mode Press ResizeAbout Copyrights Using the Spot Function Operating with the Remote ControlDisplaying and Setting the Break Timer Switching the Eco+Quiet ModeFreezing a Moving Image Auto Sync Auto Sync AdjustmentSelecting the Picture Mode Displaying an Enlarged Portion of an ImageWhen left-clicking Using the Remote Control as the Wireless Computer MouseWhen moving the cursor When right-clickingMenu Items Picture menuMain menu Projector adjustment PRJ-ADJ1/2 menu Press Menu Using the Menu ScreenMenu Selections Quick Start Menu ExampleMenu Selections Complete Menu Example Adjusting BrightQuick Start Menu Following items can be configured on the Quick Start MenuTo adjust the projected Image while watching itSelecting the Picture Mode Picture Adjustment Picture MenuMenu operation n Adjusting the Colors Adjusting the ImageAdjusting the Color Temperature Adjusting Hue, Saturation, or ValueEco+Quiet Selecting the Film ModeReducing Image Noise DNR Signal Type Setting Signal Adjustment SIG-ADJ MenuResolution Setting Setting the Video Setup When reproducing Ntsc signals in PAL video equipmentAdjusting the Image Position Adjusting the Projected Image SCR-ADJ MenuSetting the Resize Mode Keystone CorrectionClosed Caption Setting the OverscanSetting the On-screen Display For Americas onlyReversing/Inverting Projected Images Selecting the Setup GuideSelecting the Background Image Selecting the Wall ColorSpeaker Setting Auto Sync Auto Sync AdjustmentAuto Power Off Function Auto Restart FunctionSystem Lock Function Adjusting the Projector Function PRJ-ADJ1/2 MenuFan Mode Setting Enter the same keycode in Re- confirmCOMPUTER2 Select Keylock FunctionSelecting the Quick Start Menu Select On, then press EnterStandby Audio Out Setting the Function Button OperationStandby Mode Checking the Lamp Life StatusMaintenance Cleaning the projectorMaintenance Indicators About the temperature warning indicatorAbnormally high Are high Lower than 95F +35ºC Lamp Regarding the LampReplacing the Lamp Lamp unit Removing and Installing the Lamp UnitRemove the lamp unit cover STANDBY/ON button AC socketResetting the Lamp Timer Connecting Pin Assignments COMPUTER/COMPONENT input and COMPUTER/COMPONENT outputUSB Terminal Type B USB connector Communication conditions RS-232C Specifications and CommandsComputer control Basic formatCommands ProjectorERR Video Video Input Picture Mode Standard OK or ERR Appendix CC1 Compatibility Chart ComputerTroubleshooting 21-2453, 54 For Sharp Assistance Specifications Dimensions Kensington Security Standard connector ·················13 Index