Operation

Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER or SELECT. On your external test pattern source, select a pattern like the one shown in Figure 4-5.Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them.

Figure 4-5. Typical Test Pattern for Adjusting Sharpness

Use the controls in the Input Position Menu to fine-tune the aspect ratio and image position for the current source.

The input position settings are automatically saved for each input and

Note resolution.

Left/Right: Select Left/Right from the Input Position menu to shift the projected image horizontally. Press to shift the image to the right; press to shift it to the left.

Up/Down: Select Up/Down from the Input Position menu to shift the projected image vertically. Press to shift the image upward; press to shift it downward.

Width: Select Width from the Input Position menu to change the projected image width. Press to increase the width; press to decrease it.

Height: Select Height from the Input Position menu to change the projected image height. Press to increase the height; press to decrease it.

Input Position

Input Position

Left/Right

Up/Down

Width

Height

Overscan

Phase

Vidikron Vision Model 110 Installation/Operation Manual

53

Image 67
Contents 110 Page For Projectors, Video Processors and Controllers TWO Year Limited WarrantyEffective Warranty Date Vidikron Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part 1Table of Contents Operation Attach Lens Mounting Assembly to Lens Motor Carriage PlateMaintenance and Troubleshooting Table of Contents Xii 1List of Figures List of Figures Xiv About This Manual 1IntroductionIf you need Turn to Using This ManualVision 110 offers these key features and benefits Description, Features and BenefitsOptional Accessories Vision 110 at a Glance Controls and FunctionsVision 110 Rear Panel Vision 110 Rear PanelSTAND-BY LED Volt 750 mA Trigger Outputs Vision 110 Rear Connector PanelService only For future use RS-232/485 Control PortHD3 Input Hdmi I 1 / Hdmi II 2 DigitalVision 110 Remote Control Vision 110 Remote ControlVID S-Video Picture Adjustment Buttons BRT BrightnessOn / OFF Source Selection ButtonsLbox Letterbox Memory Preset ButtonsAspect Ratio Selection Buttons 169Remote Control 3InstallationOperation If installing a Vision 110/CineWide or Vision Quick SetupInstallation Overview Step Procedure For Details, Refer toAdvantages Considerations Installation ConsiderationsProjector Installation Options Installation TypeVision 110 Lens Options and Throw Ratios Position Ceiling InstallationFloor Installation Vertical and HorizontalHorizontal Lens Shift Example only Folded Optics Vision 110 Vertical and Horizontal Lens Shift LimitsInstalling the Primary Projection Lens Disconnection or lens damage Installing the Optional CineWide Lens Mount 6shows the Vision 110/CineWide with AutoScope motor assembly Remove Vision 110 with Ceiling Mount Adapters/Projector Stands AutoScope Lens Motor Installation Installing the Fixed CineWide Base Plate Vision 110/CineWide Angle Adjusting the ProjectionMounting the Vision Floor Mounting Upright Ceiling Mounting Inverted110 Connecting SourceConnections to the Vision Hdmi Connections See Figure11. Digital DTV RGB or Component Video Connections HD1, HD2 DTV or Progressive Component YPbPr Source 12. Digital DTV RGB or Component Video Connections HD313. Analog RGB Connections Analog Computer RGB Connections See FigureDVD Player, VCR Satellite Receiver Laser Disc etc Video/Composite Video Connections See Figure15. RS-232 Control System Connection ConnectionAutoScope Lens Motor Rear Connecting 12-volt Trigger Outputs to External EquipmentRear Panel Rear Panel Connecting an External IRPower source Receiver to the VisionAdjusting the Picture Orientation Turning on the PowerFocus Primary Lens AdjustmentsZoom Primary lens is perfectly centered on the screen Installing and Adjusting the CineWide Anamorphic Lens19. Attaching the Anamorphic Lens to the Lens Adapter Ring Adjusting the Horizontal X Lens Position Installation Anamorphic Lens Top View Adjusting the Geometry 4Operation Using the On-Screen MenusAspect Ratio Memory PresetsService Input SourceInput Source Main MenuAspect Ratio Hdtv programs in their native Aspect Ratio SettingsDescription 169Picture Picture Typical Pluge Pattern for Adjusting Brightness Perform the adjustments in the order listed hereGray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Input PositionInformation Memory PresetsMemory Presets InformationCalibration ISF Night CalibrationISF Day Gain/Offset Refer to ISF Night Display Color, above OSD Position To adjust the menu and press Enter orService ServiceHD Format Presets Lamp Replacement 5Maintenance and TroubleshootingFilter Replacement Troubleshooting Chart Troubleshooting TipsSymptom Possible Causes Maintenance and Troubleshooting RS-232 Connection and Port Configuration Serial Command Syntax6Serial Communications Aspect Ratio Commands Serial Commands and ResponsesCommand Description Response Input Selection CommandsEnter or Select button Command Description Response Image Preset CommandsMenu Navigation Commands Picture Adjust CommandsSerial Communications Vision 110 Specifications 7SpecificationsDimensions Home Theater Calibration SpecificationsIndustry-Standard Specifications Power RequirementsVision 110/CineWide with AutoScope Dimensions Vision 110 DimensionsSupported Timings Supported Signal Timings by InputFormat Resolution Frequency HD 1/HD 2/HD Specifications Page Vidikron