Altinex MT107-103 manual MjCn, Recall Matrix on POWER-UP, Mode

Page 17

MULTITASKER

Input Cards

 

4

3

2

 

1

 

 

 

 

 

1d

1c

1b

 

1a

 

 

 

 

 

2d

2c

2b

 

2a

 

 

 

 

 

3d

3c

3b

 

3a

 

 

 

 

 

4d

4c

4b

 

4a

 

 

 

 

 

5d

5c

5b

 

5a

 

 

 

 

 

6d

6c

6b

 

6a

 

 

 

 

 

7d

7c

7b

 

7a

 

 

 

 

 

8d

8c

8b

 

8a

 

 

 

 

 

Output Cards

1

2

3

4

 

 

 

 

1a

1b

1c

1d

 

 

 

 

2a

2b

2c

2d

 

 

 

 

3a

3b

3c

3d

 

 

 

 

4a

4b

4c

4d

 

 

 

 

5a

5b

5c

5d

 

 

 

 

6a

6b

6c

6d

 

 

 

 

7a

7b

7c

7d

 

 

 

 

8a

8b

8c

8d

 

 

 

 

18.[MjCn]

This command selects the matrix to be active.

Command Format: [MjCn]

j = Matrix ID (j = # from 1 to 9)

Cn = Card ID (n = slot # from 1 to max slots)

Example:

There is a Matrix Engine in slot 8. Send the command [M1C8] to recall the Matrix 1 configuration of C8.

RECALL MATRIX ON POWER-UP

In order to make Matrix 1’s configuration the default when power is turned on, send the

Example 2: [MAT1;16;16;00;00;02;00;C8S]

Inputs = 16

Outputs = 16

Input Offset = 00

Output Offset = 00

Width = 02

Spacing = 00

In this configuration, if Input 1 is connected to Output 16, the entire channel, 1a and 1b, will be switched to outputs 16a and 16b respectively.

[M1C8S]. The feedback will be similar to:

[SAVED]

19.[MODE]

This command sets the matrix switch mode to blocking or non-blocking. See the following examples for command functionality.

Command Format: [MODEmCn]

m = 1 = ON, 0 = OFF

Cn = Card ID (n = slot # from 1 to max slots)

Input Cards

4

3

2

1

13a

9a

5a

1a

 

 

 

 

13b

9b

5b

1b

 

 

 

 

14a

10a

6a

2a

 

 

 

 

14b

10b

6b

2b

 

 

 

 

15a

11a

7a

3a

 

 

 

 

15b

11b

7b

3b

 

 

 

 

16a

12a

8a

4a

 

 

 

 

16b

12b

8b

4b

 

 

 

 

Output Cards

1

2

3

4

1a

5a

9a

13a

 

 

 

 

1b

5b

9b

13b

 

 

 

 

2a

6a

10a

14a

 

 

 

 

2b

6b

10b

14b

 

 

 

 

3a

7a

11a

15a

 

 

 

 

3b

7b

11b

15b

 

 

 

 

4a

8a

12a

16a

 

 

 

 

4b

8b

12b

16b

 

 

 

 

Example: NON-BLOCKING

Send the command [MODE0C8] to turn off blocking for the engine in slot 8. Next, send the command [I1O*C8] to connect Input 1 to all outputs. In non-blocking mode, the inputs will be switched and the outputs will be enabled.

Example: BLOCKING ON

Send the command [I1O*C8] to connect Input 1 to all outputs. With blocking on, Input 1 will be connected to all outputs, but only output 1 will be enabled. The remaining outputs will need to be enabled using the [ON] command.

Connecting a single output results in the output being switched and enabled. For example, sending [I22O22C8] with blocking on results in Input 22 being connected to Output 22, with Output 22 being enabled.

400-0367-005

16

Image 17
Contents 64X64 Audio Matrix Switcher Card USER’S Guide Table of Contents Installation Precautions / Safety WarningsCleaning GeneralAbout Your MT107-103 Technical SpecificationsProduct Description Diagram 1 Typical Configuration Application Diagrams64X64 Matrix Diagram 2 Internal ViewMT107-103, 64X64 Audio Matrix Engine Operation Installing Your MT107-103RS-232 Control 1 RS-232 InterfaceCommand Organization Description of CommandsBasic Commands VERCnS OUTVisoff SavedSIO …S SaveCLR TestFBD Feedback Control10. ? 11. ?COn 111100000 .. C08 OL 000000000 ...0 C08 ACKC8 AFBACK STA1STA0 Matrix SetupFeedback MATInput Cards Output Cards Default ConfigurationMode Recall Matrix on POWER-UPMjCn 21. on ONmmOFFmm OFFOUTmmS SW Switch28. …P Path SELSDI 31. +VOL RSI ID CommandsSDO SIDnCi SIDnSID+ RSNRMC 41. WRRMG 44. RDSIO VERCLR TestMenu Command Definitions Menu ModeUsing Menu Mode 08 MT107-103Menu Types Menu Mode Examples4 MT107-103 Menus MT107-103 Main MenuLED is Blinking RED Troubleshooting GuideLED is not LIT No Sound Limited WARRANTY/RETURN PoliciesAltinex Policies