Altinex MT107-103 manual STA0, Feedback, Matrix Setup

Page 15

MULTITASKER

Example 1:

Command = [ON1C8]

Feedback =

(ON11110000…C08)

ON

= Output status

11110000 = Output ON/OFF

Outputs 1-4 are on, 5-8 are off, and 9-16 are not shown.

C08 = Card slot number

Example 2:

Command = [MODE=0C8]

Feedback = (MM0C08)

MM= Blocking mode

0 = Non-blocking

C08 = Card slot number

15.[STA0]

This command disables automatic feedback from the card and front panel. The command affects any card with auto-feedback capability, not just the MT107-103. The default at power-on or reset is STA0, OFF.

Command Format: [STA0]

16.[...F] – FEEDBACK

After processing a command, an OK or [ERR001] will be returned as feedback if "F" is included at the end of a command string.

Send command with AFB on and without “F”: [I1O*C8] [ ]

Send command with AFB off and without “F”: [I1O*C8]

Send command with AFB on and with “F”: [I1O*C8F] OK

Send command with AFB off and with “F”: [I1O*C8F] OK

MATRIX SETUP

The matrix setup commands define the size and configuration of a matrix. Several matrices can be defined for a single engine, although only one is typically used.

17.[MAT]

This command sets the matrix configuration for the matrix engine. The properties shown in 2-digit format MUST be entered in 2-digit format.

Command Format:

[MATj;mm;ww;xx;yy;kk;ll;CnS]

j= Matrix ID (j = # from 1 to 9) mm = Inputs (2-digit # from 01-64) zz = Outputs (2-digit # from 01-64) xx = Input offset (2-digit # from 00-99) yy = Output offset (2-digit # from 00-99 kk = Channel width (2-digit # from 01-32)

ll = Channel spacing (2-digit # from 00-31) Cn = Engine card slot number

(The left-most slot number of the engine card is the slot number to use.)

S = Save

This property saves the configuration to memory, and allows the configuration to be recalled any time, even after power-up or reset.

Adding the “S” to the command will also make the matrix configuration the default at power-up. The last configuration ID created and saved will be the default at power-up.

In order to change the power-up default without having to redefine the settings, see the command [MjCnS].

400-0367-005

14

Image 15
Contents 64X64 Audio Matrix Switcher Card USER’S Guide Table of Contents General Precautions / Safety WarningsInstallation CleaningAbout Your MT107-103 Technical SpecificationsProduct Description Diagram 1 Typical Configuration Application DiagramsDiagram 2 Internal View MT107-103, 64X64 Audio Matrix Engine64X64 Matrix 1 RS-232 Interface Installing Your MT107-103Operation RS-232 ControlVER Description of CommandsCommand Organization Basic CommandsSaved OUTCnS VisoffTest …S SaveSIO CLR11. ?C Feedback ControlFBD 10. ?On 111100000 .. C08 OL 000000000 ...0 C08 STA1 AFBACKC8 ACKMAT Matrix SetupSTA0 FeedbackInput Cards Output Cards Default ConfigurationRecall Matrix on POWER-UP MjCnMode OFF ONmm21. on OFFmmSEL SW SwitchOUTmmS 28. …P Path31. + VOLSDI ID Commands SDORSI RSN SIDnSIDnCi SID+44. RD 41. WRRMC RMGTest VERSIO CLR08 MT107-103 Menu ModeMenu Command Definitions Using Menu ModeMT107-103 Main Menu Menu Mode ExamplesMenu Types 4 MT107-103 MenusTroubleshooting Guide LED is not LITLED is Blinking RED Limited WARRANTY/RETURN Policies Altinex PoliciesNo Sound