MULTITASKER

CARD CONTROL

Card control commands allow the main functions of the card to be executed over the RS-232 bus, or from the front panel’s programmable keys.

20.[ONmm]

This command turns on a single output.

Command Format: [ONmmCn]

mm= Output Number (mm = # from 01 to 64) Cn = Card ID (n = slot # from 1 to max slots) Example:

There is an MT107-103in slot 8. Turn on output number 64 by sending [ON64C8].

21.[ON]

This command turns on all outputs.

Command Format: [ONCn]

Cn = Card ID (n = slot # from 1 to max slots)

Example:

There is an MT107-103in slot 8. Turn on all outputs by sending the command [ONC8].

22.[OFFmm]

This command turns off a single output.

Command Format: [OFFmmCn]

mm= Output Number (mm = # from 01 to 64) Cn = Card ID (n = slot # from 1 to max slots) Example:

There is an MT107-103in slot 8. Turn off only Output 1 by sending [OFF1C8].

23.[OFF]

This command turns off all outputs.

Command Format: [OFFCn]

Cn = Card ID (n = slot # from 1 to max slots)

Example:

There is an MT107-103in slot 8. Turn off all outputs by sending [OFFC8].

24.[ImmOxx]

This command connects a single input to a single output.

Command Format: [ImmOxxCn]

mm= Input (2-digit # from 01 to 64) xx = Output (2-digit # from 01 to 64)

Cn = Card ID (n = slot # from 1 to max slots) Example:

Connect Input 22 to Output 32 of C8 by sending [I22O32C5].

25.[ImmO*]

This command connects a single input to all the outputs.

Command Format: [ImmO*Cn]

mm = Input (2-digit # from 01 to 64)

Cn = Card ID (n = slot # from 1 to max slots)

Example:

Connect Input 7 of C8 to all the outputs of C8 by sending [I07O*C8].

26.[INmmS]

This command displays a list of all enabled outputs that are connected to the specified input. Disabled outputs are not listed.

Command Format: [INmmSCn]

mm= Input Number (mm = # from 01 to 64) Cn = Card ID (n = slot # from 1 to max slots) Example 1:

There is an MT107-103in slot 8. Input 1 is connected to all outputs, but only Outputs 1-4 are enabled. Send the command [IN01SC8] and receive the following feedback:

[1,2,3,4C08]

400-0367-005

17

Image 18
Contents 64X64 Audio Matrix Switcher Card USER’S Guide Table of Contents Cleaning Precautions / Safety WarningsInstallation GeneralTechnical Specifications About Your MT107-103Product Description Application Diagrams Diagram 1 Typical ConfigurationDiagram 2 Internal View MT107-103, 64X64 Audio Matrix Engine64X64 Matrix RS-232 Control Installing Your MT107-103Operation 1 RS-232 InterfaceBasic Commands Description of CommandsCommand Organization VERVisoff OUTCnS SavedCLR …S SaveSIO Test10. ? Feedback ControlFBD 11. ?COn 111100000 .. C08 OL 000000000 ...0 C08 ACK AFBACKC8 STA1Feedback Matrix SetupSTA0 MATDefault Configuration Input Cards Output CardsRecall Matrix on POWER-UP MjCnMode OFFmm ONmm21. on OFF28. …P Path SW SwitchOUTmmS SEL31. + VOLSDI ID Commands SDORSI SID+ SIDnSIDnCi RSNRMG 41. WRRMC 44. RDCLR VERSIO TestUsing Menu Mode Menu ModeMenu Command Definitions 08 MT107-1034 MT107-103 Menus Menu Mode ExamplesMenu Types MT107-103 Main MenuTroubleshooting Guide LED is not LITLED is Blinking RED Limited WARRANTY/RETURN Policies Altinex PoliciesNo Sound