Table A-3 Power Output Parameter Block Values Level 2

Level 2 Blocks

Block Title

Parameter

P#

Adjustable Range

Factory

User

 

 

 

 

 

Setting

 

 

 

 

 

 

OUTPUT LIMITS

OPERATING ZONE

2001

1–STD CONST TQ

STD

 

 

 

 

2–STD VAR TQ

CONST TQ

 

 

 

 

3–QUIET CONST TQ

 

 

 

 

 

4–QUIET VAR TQ

 

 

 

 

 

 

 

 

 

MIN OUTPUT SPEED

2002

0-MAX Speed RPM

0 RPM

 

 

 

 

 

 

 

 

MAX OUTPUT SPEED

2003

0-30000 RPM

Rated Motor

 

 

 

 

 

Speed

 

 

 

 

 

 

 

 

PK CURRENT LIMIT

2004

0-PEAK RATED CURRENT

PK Control

 

 

 

 

 

Rating

 

 

 

 

 

 

 

 

PWM FREQUENCY

2005

1.0-5.0 KHZ (Standard)

2.5 KHZ

 

 

 

 

1.0-16.0 KHZ (Quiet)

 

 

 

 

 

 

 

 

 

CUR RATE LIMIT

2006

0.001-10.000 SEC

0.004 SEC

 

 

 

 

 

 

 

CUSTOM UNITS

DECIMAL PLACES

2101

0-5

5

 

 

 

 

 

 

 

 

VALUE AT SPEED

2102

0-65535 / 0-65535

00000/

 

 

 

 

 

01000 RPM

 

 

 

 

 

 

 

 

UNITS OF MEASURE

2103

Selection of 9 Character Sets

-

 

 

 

 

 

 

 

PROTECTION

OVERLOAD

2201

0–FOLDBACK, 1–FAULT

FOLDBACK

 

 

 

 

 

 

 

 

EXTERNAL TRIP

2202

0–OFF, 1– ON

OFF

 

 

 

 

 

 

 

 

LOCAL ENABLE INP

2203

0–OFF, 1– ON

OFF

 

 

 

 

 

 

 

 

FOLLOWING ERROR

2204

0–OFF, 1– ON

OFF

 

 

 

 

 

 

 

 

TORQUE PROVING

2205

0–OFF, 1– ON

OFF

 

 

 

 

 

 

 

MISCELLANEOUS

RESTART AUTO/MAN

2301

0–MANUAL, 1–AUTOMATIC

MANUAL

 

 

 

 

 

 

 

 

RESTART FAULT/HR

2302

0-10

0

 

 

 

 

 

 

 

 

RESTART DELAY

2303

0-120 SECONDS

0 SEC

 

 

 

 

 

 

 

 

FACTORY SETTINGS

2304

0–NO, 1–YES

NO

 

 

 

 

 

 

 

 

HOMING SPEED

2305

0-MAX Speed

100 RPM

 

 

 

 

 

 

 

 

HOMING OFFSET

2306

0-65535 Encoder Counts

1024 CNTS

 

 

 

 

 

 

 

SECURITY

SECURITY STATE

2401

0–OFF

OFF

 

CONTROL

 

 

1–LOCAL SECURITY

 

 

 

 

 

2–SERIAL SECURITY

 

 

 

 

 

3–TOTAL SECURITY

 

 

 

 

 

 

 

 

 

ACCESS TIMEOUT

2402

0-600 SEC

0 SEC

 

 

 

 

 

 

 

 

ACCESS CODE

2403

0-9999

9999

 

 

 

 

 

 

 

MOTOR DATA

MOTOR VOLTAGE

2501

150-999 VOLTS

Factory Set

 

 

 

 

 

 

 

 

MOTOR RATED AMPS

2502

0-999.9

Factory Set

 

 

 

 

 

 

 

 

MOTOR RATED SPD

2503

0-32767 RPM

1750 RPM

 

 

 

 

 

 

 

 

MOTOR RATED FREQ

2504

0-500.0 Hz

60.0 Hz

 

 

 

 

 

 

 

 

MOTOR MAG AMPS

2505

0-0.54 AMPS

CALC

 

 

 

 

 

 

 

 

ENCODER COUNTS

2506

0-65535 CNTS

1024 PPR

 

 

 

 

 

 

 

 

RESOLVER SPEEDS

2507

0 to 10

1 SPEED

 

 

 

 

 

 

 

 

CALC PRESETS

2508

0–NO, 1–YES

NO

 

 

 

 

 

 

 

MN722

Appendix A-5

Page 114
Image 114
Baldor mn722 manual Table A-3 Power Output Parameter Block Values Level