Table 4-4 Inverter Control Board Level 1 Parameter Definitions
Block Title | Parameter | Description |
|
|
|
PRESET | Preset Speeds | Allows selection of 15 predefined motor operating speeds. |
SPEEDS | #1 – #15 | Each speed may be selected using external switches connected to |
|
| |
|
| For motor operation, a motor direction command must be given along with a preset |
|
| speed command. |
|
|
|
ACCEL/DECEL | Accel Time #1,2 | Accel time is the number of seconds required for the motor to increase at a linear rate |
RATE |
| from 0 RPM to the RPM specified in the “Max Output Speed” parameter in the Level 2 |
|
| Output Limits block. |
| Decel Time #1,2 | Decel time is the number of seconds required for the motor to decrease at a linear rate |
|
| from the speed specified in the “Max Output Speed” parameter to 0 RPM. |
| ||
|
| and stops. Half of programmed |
|
| 0% represents no “S” and 100% represents full “S” with no linear segment. |
|
| Note: Accel #1, Decel #1 and |
|
| Accel #2, Decel #2 and |
|
| associations can be used to condition any Preset Speed or External Speed |
|
| command. |
|
| Note: If drive faults occur during rapid Accel or Decel, selecting an |
|
| eliminate the faults. |
|
|
|
JOG SETTINGS | Jog Speed | Jog Speed is the programmed speed used during for jog. Jog can be initiated from the |
|
| keypad or terminal strip. At the Keypad, press the JOG key then press and hold the |
|
| FWD or REV. For Standard Run, close the JOG input |
|
| the direction input |
|
| Process Control mode operation is different. If the terminal strip Process Mode |
|
| Enable input |
|
| cause the drive to move in the direction of the error (without pressing FWD or REV). |
| Jog Accel Time | Jog Accel Time changes the slope of the jog accel ramp. It is the time from zero speed |
|
| to maximum speed programmed in seconds. |
| Jog Decel Time | Jog Decel Time changes the slope of the jog decel ramp. It is the time from maximum |
|
| speed to zero speed programmed in seconds. |
| Jog | Jog |
|
|
|
Figure 4-2 40% S-Curve Example
SpeedOutput
0
20
%
| 40% |
| Curve |
0% | 20 |
Curve | % |
Accel Time
Accel
Output Speed
0
20
%
40% Curve
0%
Curve
20
%
Decel Time
Decel
MN722 | Programming & Operation |