Baldor Keypad

The keypad is used to program the control parameters, operate the motor and monitor

 

the status and outputs of the control by accessing the display options, diagnostic menus

 

and the fault log.

Figure 4-1 Keypad

JOG - (Green) lights when Jog is active.

FWD - (Green) lights when FWD direction is commanded.

REV - (Green) lights when REV direction is commanded.

STOP - (Red) lights when motor STOP is commanded.

Indicator Lights

Keypad Display - Displays status information during Local or Remote operation. It also displays information during parameter setup and fault or Diagnostic Information.

JOG - Press JOG to select the preprogrammed jog speed. After the JOG key has been pressed, use the FWD or REV keys to run the motor in the direction that is needed. The JOG key is only active in the Local mode.

FWD - Press FWD to initiate forward rotation of the motor. This key is only active in the Keypad or Local mode.

REV - Press REV to initiate reverse rotation of the motor. This key is active only in the Keypad or Local mode.

STOP - Press STOP one time to initiate a stop sequence. Depending on the setup of the control, the motor will either ramp or coast to a stop. This key is operational in all modes of operation unless it has been disabled by the Keypad Stop parameter in the Keypad (programming) Setup Block. Press STOP twice to disable control (coast to stop).

LOCAL - Press LOCAL to change between the local (keypad) and remote operation. When the control is in the local mode all other external commands to the J1 terminal strip will be ignored with the exception of the external trip input.

DISP - Press DISP to return to Display mode from Programming mode. Provides operational status and advances to the next display menu item including the diagnostic screens.

SHIFT - Press SHIFT in the program mode to control cursor movement. Pressing the SHIFT key once moves the blinking cursor one character position to the right. While in Program mode, a parameter value may be reset to the factory preset value by pressing the SHIFT key until the arrow symbols at the far left of the keypad display are flashing, then press an arrow key. In the Display mode the SHIFT key is used to adjust the keypad contrast.

RESET - Press RESET to clear all fault messages (in local mode). Can also be used to return to the top of the block programming menu without saving any parameter value changes.

PROG - Press PROG to enter the program mode. While in the Program mode the PROG key is used to edit a parameter setting.

Y- (UP Arrow).

Press Y to change the value of the parameter being displayed. Pressing Y increments the value to the next greater value. Also, when the fault log or parameter list is displayed, the Y key will scroll upward through the list. In the local mode pressing the Y key will increase motor speed to the next greater value.

ENTER - Press ENTER to save parameter value changes and move back to the previous level in the programming menu. In the Display mode the ENTER key is used to directly set the local speed reference. It is also used to select other operations when prompted by the keypad display.

B- (Down Arrow)

Press B to change the value of the parameter being displayed. Pressing B decrements the value to the next lesser value. Also, when the fault log or parameter list is displayed, the B key will scroll downward through the list. In the local mode pressing the B key will decrease motor speed to the next lower value.

4-2 Programming & Operation

MN722

Page 49
Image 49
Baldor mn722 manual Baldor Keypad