Figure 3-30 Opto-Output Equivalent Circuit
PC865 | PC865 | PC865 | PC865 |
50mA max | 50mA max | 50mA max | 50mA max |
See recommended terminal tightening torques in Section 7.
J1 |
| |
18 | Opto Output 1 | |
19 | ||
|
20Opto Output 2
21Opto Output 3
22Opto Output 4
10 – 30VDC Opto Outputs
41Opto Out 1 Return
42Opto Out 2 Return
43Opto Out 3 Return
44Opto Out 4 Return
| Check of Electrical Items | |
| CAUTION: After completing the installation but before you apply power, be | |
|
| sure to check the following items. |
| 1. | Verify AC line voltage at source matches control rating. |
| 2. | Inspect all power connections for accuracy, workmanship and tightness and |
|
| compliance to codes. |
| 3. | Verify control and motor are grounded to each other and the control is |
|
| connected to earth ground. |
| 4. | Check all signal wiring for accuracy. |
| 5. | Be certain all brake coils, contactors and relay coils have noise suppression. |
|
| This should be an |
|
| coils. MOV type transient suppression is not adequate. |
| WARNING: Make sure that unexpected operation of the motor shaft during start | |
|
| up will not cause injury to personnel or damage to equipment. |
| Check of Motor and Coupling | |
| 1. | Verify freedom of motion of motor shaft. |
| 2. | Verify that motor coupling is tight without backlash. |
| 3. | Verify the holding brakes if any, are properly adjusted to fully release and set to |
|
| the desired torque value. |
MN722 | Receiving & Installation |