Figure 3-30 Opto-Output Equivalent Circuit

PC865

PC865

PC865

PC865

50mA max

50mA max

50mA max

50mA max

See recommended terminal tightening torques in Section 7.

J1

 

18

Opto Output 1

19

 

20Opto Output 2

21Opto Output 3

22Opto Output 4

10 – 30VDC Opto Outputs

41Opto Out 1 Return

42Opto Out 2 Return

43Opto Out 3 Return

44Opto Out 4 Return

Pre-Operation Checklist

Check of Electrical Items

 

CAUTION: After completing the installation but before you apply power, be

 

 

sure to check the following items.

 

1.

Verify AC line voltage at source matches control rating.

 

2.

Inspect all power connections for accuracy, workmanship and tightness and

 

 

compliance to codes.

 

3.

Verify control and motor are grounded to each other and the control is

 

 

connected to earth ground.

 

4.

Check all signal wiring for accuracy.

 

5.

Be certain all brake coils, contactors and relay coils have noise suppression.

 

 

This should be an R-C filter for AC coils and reverse polarity diodes for DC

 

 

coils. MOV type transient suppression is not adequate.

 

WARNING: Make sure that unexpected operation of the motor shaft during start

 

 

up will not cause injury to personnel or damage to equipment.

 

Check of Motor and Coupling

 

1.

Verify freedom of motion of motor shaft.

 

2.

Verify that motor coupling is tight without backlash.

 

3.

Verify the holding brakes if any, are properly adjusted to fully release and set to

 

 

the desired torque value.

MN722

Receiving & Installation 3-35

Page 46
Image 46