Display Mode

The control is in the DISPLAY MODE at all times except when parameter values are

 

changed (Programming mode). The Keypad Display shows the status of the control as in

 

the following example.

 

 

 

 

 

 

 

 

 

Motor Status

 

 

Output Condition

 

 

 

 

Control Operation

 

 

 

Value and Units

 

 

 

 

 

 

 

 

 

The DISPLAY MODE is used to view operating status, Diagnostic INFO and the Fault

Log. The description of how to do these tasks are described on the following pages.

Adjusting Display Contrast When AC power is applied to the control, the keypad should display the status of the control. If there is no visible display, use the following procedure to adjust the contrast of the display.

(Contrast may be adjusted in display mode when motor is stopped or running)

Action

Description

 

Display

Comments

Apply Power

No visible display

 

 

 

 

 

Press DISP Key

Places control in display mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press SHIFT SHIFT

Allows display contrast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adjustment

 

 

 

 

 

Press Y or B Key

Adjusts display intensity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press ENTER

Saves level of contrast and exits

 

 

 

Typical display

 

 

 

 

 

 

 

to display mode

 

 

 

 

 

 

 

 

 

 

 

 

Display Mode Screens

 

 

 

 

 

 

 

 

 

Action

Description

 

Display

Comments

Apply Power

 

 

 

 

Logo display for 5 seconds.

 

Display mode showing motor

 

 

 

No faults present. Local keypad

 

 

 

 

 

 

 

 

speed.

 

 

 

mode. If in remote/serial mode,

 

 

 

 

 

press local for this display.

 

 

 

 

 

Press DISP key

Display mode showing custom

 

 

 

Output rate display will only

 

 

 

unit output rate.

 

 

 

appear if Value At Speed

Press DISP key

Display Frequency

 

 

 

parameter is entered.

 

 

 

 

 

 

 

 

 

 

 

 

Press DISP key

DIsplay Current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press DISP key

DIsplay Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press DISP key

Combined DIsplay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press DISP key

Screen to enter Fault Log

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press DISP key

Screen to enter Diagnostic Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press DISP key

Exit Display mode and return to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor Speed display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MN722

Programming & Operation 4-3

Page 50
Image 50
Baldor mn722 manual Display Mode Screens, Action Description Display Comments