How to Access Diagnostic Information

Action

Description

 

Display

 

 

Comments

 

 

 

 

 

 

 

Apply Power

 

 

 

 

 

Logo display for 5 seconds.

 

 

 

 

 

 

Display mode showing motor

 

 

 

 

No faults present. Local keypad

 

 

 

 

 

 

 

 

 

 

speed.

 

 

 

 

mode. In remote/serial mode,

 

 

 

 

 

 

disable drive then press local for

 

 

 

 

 

 

 

 

 

 

 

 

this display.

Press DISP key 6 times

Scroll to Diagnostic Information

 

 

 

 

Diagnostic Access screen.

 

 

 

 

screen

 

 

 

 

 

Press ENTER key

Access diagnostic information.

 

 

 

 

First Diagnostic Information

 

 

 

 

 

 

 

 

 

 

 

 

 

screen.

Press DISP key

Display showing control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature.

 

 

 

 

 

Press DISP key

Display showing bus voltage.

 

 

 

 

 

 

 

 

 

 

 

XXXV

 

 

 

 

 

 

 

 

Press DISP key

Display showing % overload

 

 

 

 

 

 

 

 

 

 

current remaining.

 

 

 

 

 

Press DISP key

Display showing opto inputs &

 

 

 

 

Opto Inputs states (Left);

 

 

 

 

 

 

 

 

outputs states.

 

 

 

 

Opto Outputs states (Right).

 

0=OPEN, 1=CLOSED.

 

 

 

 

 

 

 

 

 

 

Press DISP key

Display showing actual drive

 

 

 

 

HR.MIN.SEC format.

 

 

 

 

running time.

 

 

 

 

 

Press DISP key

Display showing operating zone,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage and control type.

 

 

 

 

 

Press DISP key

Display showing continuous

 

 

 

 

ID is displayed as a hexadecimal

 

 

 

 

 

 

 

 

amps; PK amps rating; amps/volt

 

 

 

 

value.

 

scale of feedback, power base ID.

 

 

 

 

 

 

 

 

 

 

Press DISP key

Display showing which Group1 or

 

 

 

 

 

 

 

 

 

 

2 expansion boards are installed

 

 

 

 

 

 

and recognized.

 

 

 

 

 

 

 

 

 

 

Press DISP key

Display showing motor shaft

 

 

 

 

 

 

 

 

 

 

revolutions from the REV home

 

 

 

 

 

 

set point.

 

 

 

 

 

 

 

 

 

 

Press DISP key

Display mode showing parameter

 

 

 

 

 

 

 

 

 

 

table selected.

 

 

 

 

 

Press DISP key

Display showing software version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and revision installed in the

 

 

 

 

 

 

control.

 

 

 

 

 

 

 

 

 

 

Press DISP key

Displays exit choice.

 

 

 

 

Press ENTER to exit diagnostic

 

 

 

 

 

 

 

 

 

information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-6 Troubleshooting

MN722

Page 75
Image 75
Baldor mn722 manual How to Access Diagnostic Information, Xxxv